CMCS -MAINTENANCE PLANNING DIALOG BOX
EFFECTIVITY BEJ ALL 45-10-00
Page 98.123
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
THIS PAGE IS INTENTIONALLY LEFT BLANK
45-10-00
Page 98.124 D633W101-BEJ Jan 05/2002
CMCS -MAINTENANCE PLANNING -INBOUND MAINTENANCE MEMO SUMMARY DISPLAY
General
The inbound maintenance memo summary display shows all maintenance messages that are correlated to maintenance memos that occurred in present flight leg.
Maintenance memos are a group of maintenance messages that give information about the condition of redundant LRU/ systems.
These memos let the maintenance organizations monitor the deterioration of a component/system. They also let the maintenance organizations plan the appropriate maintenance actions before a system or component becomes not airworthy.
A maintenance memo normally shows one fault away from a fault that will cause a status message.
Maintenance memos are either active, latched, or not active. Latched messages are those that occur in a particular flight phase and are in the memory of the LRU.
Maintenance memos are correlated to one or more maintenance messages.
The inbound maintenance memo summary display shows the maintenance memos by time (the newest memo shows first) or by ATA.
EFFECTIVITY
BEJ ALL
The inbound maintenance memo summary display shows this:
*
Header information
*
Fault summary field
*
Buttons.
Header Information
The header information includes:
*
Display title
*
Instructions to access the single maintenance message summary display
*
Tail identification
*
Flight leg ID with origin and destination airports
*
Flight leg start time and date
*
Source of information.
Fault Summary Field
The fault summary field includes:
*
Fault summary field title
*
Number of items
*
Maintenance memo summary groups.
The fault summary field title shows above the fault summary on the left side. The title is Maintenance Memos recorded during the Inbound Leg.
The number of items shows above the scroll bar. The number shows the total number of memo summary groups.
45-10-00
Page 98.125 D633W101-BEJ Sep 05/2002
CMCS -MAINTENANCE PLANNING -INBOUND MAINTENANCE MEMO SUMMARY DISPLAY
Buttons
Select MAINTENANCE MESSAGE DATA to show the single maintenance message display.
EFFECTIVITY BEJ ALL 45-10-00
Page 98.126
D633W101-BEJ Sep 05/2002
CMCS -MAINTENANCE PLANNING -INBOUND MAINTENANCE MEMO SUMMARY DISPLAY
EFFECTIVITY BEJ ALL 45-10-00
Page 98.127
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
THIS PAGE IS INTENTIONALLY LEFT BLANK
45-10-00
Page 98.128 D633W101-BEJ Sep 05/2002
CMCS -MAINTENANCE PLANNING -EXISTING MAINTENANCE MEMO SUMMARY DISPLAY
General
The existing maintenance memo summary display shows all maintenance memos that are currently active or latched.
Maintenance memos are a group of maintenance messages that give information about the condition of redundant LRU/ systems.
These memos let the maintenance organizations monitor the deterioration of a component/system. They also let the maintenance organizations plan the appropriate maintenance actions before a system or component becomes not airworthy.
A maintenance memo normally shows one fault away from a fault that will cause a status message.
Maintenance memos are either active or latched. Latched messages are those that occur in a particular flight phase and are in the memory of the LRU.
Maintenance memos are correlated to one or more maintenance messages.
The existing maintenance memo summary display shows the maintenance memos by time (the newest memo shows first) or by ATA.
EFFECTIVITY
BEJ ALL
The existing maintenance memo summary display shows:
*
Header information
*
Fault summary field
*
Buttons.
Header Information
The header information includes:
*
Display title
*
Instructions to access the single maintenance message summary display
*
Tail identification
*
Time and date
*
Source of information.
Fault Summary Field
The fault summary field includes:
*
Fault summary field title
*
Number of items
*
Maintenance memo summary groups