Interactive dialog box
*
Menu abort dialog box.
When you meet all unique requirements, the special function display shows with status and instructions for the special function.
Special Functions Selection Dialog Box
The special functions selection dialog box has:
*
Title
*
Select ATA list box
*
Select function list box
*
Button area.
Select ATA List Box
The select ATA list box shows the airplane systems in ATA order. You must choose an ATA system first. This selection causes the functions for that ATA to become available.
Select Function List Box
The select function area list box has all the LRUs in the ATA that have a special function available.
The selection of the LRU with a special function makes the CONTINUE command available.
Button
Select CONTINUE to show the precondition dialog box on top of the ground test selection dialog box for the selected special function.
Select HELP to show the help dialog box for the special function dialog box. Help text for the dialog box must be in the CMCF AMI for HELP to show.
Select GO BACK to remove the special function selection dialog box and to return to the previous display.
EFFECTIVITY BEJ ALL 45-10-00
Page 98.212
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
CMCS -SPECIAL FUNCTIONS DIALOG BOX
EFFECTIVITY BEJ ALL 45-10-00
Page 98.213
D633W101-BEJ Sep 05/2002
CMCS -SPECIAL FUNCTIONS PRECONDITION DIALOG BOX
General
The special functions precondition dialog box is similar to the ground test precondition dialog box. The special functions precondition dialog box contains:
*
Title
*
Special function title
*
Special function description
*
Precondition list
*
Buttons.
Special Function Title
The special function title shows the name from the selection made on the special function selection dialog box.
Special Function Description
The test description is a brief description about the special function.
Precondition List
The precondition list gives instructions to follow before you run the special function.
The precondition display database stores the special function description and the precondition list.
Buttons
The precondition dialog box shows four buttons.
Select CONTINUE to close the special function selection dialog box (if open), the precondition dialog box, and to show the special function display.
Select REPORT DATA to show the report dialog box.
Select HELP to show the help dialog box for the special function precondition dialog box. Help text for the dialog box must be in the CMCF AMI for HELP to show.
Select GO BACK to remove the precondition dialog box and to return to the previous display.
EFFECTIVITY BEJ ALL 45-10-00
Page 98.214
D633W101-BEJ Sep 05/2002
CMCS -SPECIAL FUNCTIONS PRECONDITION DIALOG BOX
EFFECTIVITY BEJ ALL 45-10-00
Page 98.215
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
THIS PAGE IS INTENTIONALLY LEFT BLANK
45-10-00
Page 98.216 D633W101-BEJ Sep 05/2002
CMCS -SPECIAL FUNCTION MAIN DISPLAY
General
The SPECIAL FUNCTION main display supplies status information and control for the special functions.
The SPECIAL FUNCTION display shows this data:
*
Display title
*
ATA chapter and name
*
Special function title
*
FUNCTION CONDITION messages
*
Function control selections
*
Text field
*
Text field title
*
Buttons.
ATA Chapter and Name
This field shows the ATA chapter and system name from the initial selection on the special functions selection dialog box.
Special Function Title
This field shows the system function title from the initial selection on the special function selection dialog box.
Function Condition Messages and Control Selections
The function condition messages field can show these messages:
* READY
EFFECTIVITY
BEJ ALL
*
INHIBITED
*
CAN NOT OPERATE
*
OPERATING
*
STOPPED
*
COMPLETE.
These are the possible function control buttons:
*
START FUNCTION
*
STOP FUNCTION
*
OPERATE FUNCTION AGAIN
*
TO START FUNCTION.
READY shows when no inhibits or no interference conditions exist. The START FUNCTION button shows adjacent to the READY message.
中国航空网 www.aero.cn