• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-29 11:48来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

Sampling field

*
Header field

*
Scale header field

*
Sampling data field

*
Sampling data field heading.

 

Use the direct entry field to enter signal parameters with the keyboard.
The sampling field shows the word Sampling when the CMCF receives a valid signal from an LRU/LRM. The word Sampling goes away for an invalid signal or for no input.
The header field shows WORD NO and/or BIT NO to help identify the information in the scale header field.
The scale header field shows the 629 word counts and bit counts for the data in the sampling field. The characters in the header field line up to identify the characters in the sampling field.
The sampling data field has the most recent data available to the display.
Buttons
The FREEZE button is a toggle with RUN. The display shows RUN first with the system in the freeze mode.
RUN is available when there is a signal to monitor. Select RUN to start the data to update at a 1 HZ rate. The selection toggles to FREEZE. FREEZE causes the CMCF to stop the update.
Select UNITS to show the INPUT MONITORING UNITS dialog box.

EFFECTIVITY BEJ ALL  45-10-00 
Page 98.157 
D633W101-BEJ  Sep 05/2002 

 

CMCS -INPUT MONITORING ARINC 629 FULL WORD STRING DISPLAY
Select UPDATE DISPLAY to update the word string one time only. This selection is available with a valid ARINC 629 entry. This selection is not available when FREEZE shows. The word string is sampling at this time.
EFFECTIVITY BEJ ALL  45-10-00 
Page 98.158 
D633W101-BEJ  Sep 05/2002 

 


CMCS -INPUT MONITORING ARINC 629 FULL WORD STRING DISPLAY

EFFECTIVITY BEJ ALL  45-10-00 
Page 98.159 
D633W101-BEJ  Sep 05/2002 

 

CMCS -INPUT MONITORING INVALID ENTRY DIALOG BOX

General

The input monitoring INVALID ENTRY dialog box shows when you select the CONTINUE button after an invalid signal entry.
The dialog box includes a message and two buttons.
Dialog Box Message
The message is INVALID ENTRY.
Buttons

Select GO BACK to remove the dialog box and return to the previous display.
Select HELP to show the help dialog box for the input monitoring INVALID ENTRY dialog box. Help text for the dialog box must be in the CMCF AMI for HELP to show.
EFFECTIVITY BEJ ALL  45-10-00 
Page 98.160 
D633W101-BEJ  Sep 05/2002 

 


CMCS -INPUT MONITORING INVALID ENTRY DIALOG BOX

EFFECTIVITY BEJ ALL  45-10-00 
Page 98.161 
D633W101-BEJ  Sep 05/2002 

 


777 AIRCRAFT MAINTENANCE MANUAL


THIS PAGE IS INTENTIONALLY LEFT BLANK

45-10-00


Page 98.162 D633W101-BEJ Jan 05/2002


CMCS -CMCF OPTIONS DIALOG BOX

General

Use the CMCF options dialog box to select CMCF options. The dialog box shows the list of nonexclusive options.
The dialog box also shows the hexadecimal code for the CMCF operational program configuration (OPC) options and the hexadecimal code for the airline modifiable information (AMI).
The OPC options define functional requirements for the CMCF.
The AMI is a file that the airlines create on the ground based software tool (GBST) and load into the CMCF.
The dialog box has this information:
*
A title

*
CMCF options list box

*
OPC and AMI list box

*
Buttons.


CMCF Options List Box

The options list box shows up to 50 options. You can select or deselect any combination of the options to meet specific requirements.
The list box has a scroll bar and a text field that shows the number of options in the list.
EFFECTIVITY
BEJ ALL

There is one central maintenance option:
* Store all FDE’s between Takeoff and Rollout.
Select Store all FDE’s between Takeoff and Rollout to store all correlated and non-correlated flight deck effects that occur between the takeoff roll and rollout flight phases.
OPC and AMI List Box
The OPC and AMI list box shows the hexadecimal code for the options in each category.
There are up to 64 OPC configuration options.
There are up to 50 AMI configuration options.
Convert the hexadecimal code to binary. A (1) shows when the option is enabled. A (0) shows when the option is disabled.
Buttons
When you select MAKE CHANGE, the CMCF does this:
*
Accepts the option change

*
Closes the dialog box

*
Sends the new option data to the offside CMCF.


45-10-00

Page 98.163 D633W101-BEJ Sep 05/2002

 

CMCS -CMCF OPTIONS DIALOG BOX
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:777 AMM 飞机维护手册 中央维护 Central Maintenance(57)