• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-21 08:00来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 S 752-053
 (17) Make sure Smoke Detector Blower 2 (M10463) stops and Smoke Detector Blower 1 starts to operate.
 E. Do the procedure for the Aft Cargo Compartment
 S 752-054
 (1)  
Make sure Smoke Detector Blower 3 (M10464) operates.

 S 032-055

 (2)
Remove the screws which hold Smoke Detector Blower 4 (M10465).

 S 012-056

 (3)  
To get access to the flapper valve remove Smoke Detector Blower 4. Be careful not to disconnect or cause kinks in the hoses.

 S 752-057

 (4)  
Make sure the open end around the flapper valve is free of dirt which will prevent a correct position of the valve.

 S 862-058

 (5)  
Move the valve from side to side to the direction of the open end. Make sure the valve is in the correct position and does not stick because of remaining material

 S 422-059

 (6)  
Install Smoke Detector Blower 4 and use the screws which were removed.

 S 862-060

 (7)  
Open this circuit breaker on the P70 panel:


 (a)  70B12, SMOKE DET BLOWER 3
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-16-05
 ALL  ú ú 07 Page 206 ú Dec 20/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

 (8)  S 752-061Make sure Smoke Detector Blower 4 (M10465) operates.
 (9)  S 032-062Remove the screws which hold Smoke Detector Blower 3 (M10464).
 S 012-063

 (10)
 To get access to the flapper valve remove Smoke Detector Blower 3. Be careful not to disconnect or cause kinks in the hoses.

 S 752-064

 (11)
 Make sure the open end around the flapper valve is free of dirt which will prevent a correct position of the valve.

 S 862-065

 (12)
 Move the valve from side to side to the direction of the open end. Make sure the valve is in the correct position and that it can move freely.

 S 422-066

 (13)
 Install Smoke Detector Blower 3 and use the screws which were removed.

 S 862-067

 (14)
 Close this circuit breaker on the P70 panel:


 (a) 70B12, SMOKE DET BLOWER 3
 S 862-068
 (15) Open and then close these circuit breakers on the P11 panel to set the smoke detector blower system:
 (a) 11S35, FIRE DET CARGO CONT or CARGO SMOKE BLOWER CONT
 S 752-069
 (16) Make sure Smoke Detector Blower 4 (M10465) stops and Smoke Detector Blower 3 (M10464) starts to operate.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-16-05
 ALL  ú ú 04 Page 207 ú Dec 20/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

 S 022-092
 (17)
 Close the cargo doors (AMM 52-34-00/201).

 S 862-070

 (18)
 Remove electrical power (AMM 24-22-00/201) if it is not necessary.


 TASK 26-16-05-302-071
 4. Flapper Valve Removal/Installation (Fig. 201)
__________________________________
 A. Reference
 (1)  
AMM 26-16-02/401, Smoke Detector Blowers

 (2)  
AMM/24-22-00/201, Electrical Power - Control

 (3)  
AMM 52-34-00/201, No. 1 and No. 2 Cargo Door


 B. Access
 (1)  
Location Zones
 121/122 Forward Cargo Compartment
 153/154 Aft Cargo Compartment
 820 Lower Half of Fuselage (RH side)


 (2)  
Access Panels
 821 Forward Cargo Compartment Door
 822 Aft Cargo Compartment Door
 823 Bulk Cargo Compartment Door

 

 C. Do the Procedure
 S 012-093
 (1)  
Open main cargo door (AMM 52-34-00/201).

 S 012-087

 (2)
Remove the applicable smoke detector blower (AMM 26-16-02/401).

 S 322-072

 (3)  
Drill out the rivets to remove the flapper valve (three per valve). Keep the backup plate.

 S 322-073
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 防火 FIRE PROTECTION 1(95)