• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-21 08:00来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (b)  
11B21, FIRE DETECTION L ENGINE 2

 


 S 865-020
 (6)
Connect a jumper wire between the two terminals on each of these switches which are installed on the No. 1 strut upper spar.

 (a)  
S10194

 (b)  
S10198

 

 (7)  
Push the ECS MSG switch on the EICAS maintenance panel.

 S 755-022

 (8)  
Make sure these indications occur:

 (a)  
The L ENG OVHT light on the pilots aft control stand, P8, comes on.

 (b)  
The EICAS message L ENG OVHT shows on the top display.

 (c)  
The EICAS messages L STRUT OH DET 1 and L STRUT OH DET 2 show on the bottom display.

 (d)  
The caution annunciation is heard.

 (e)  
The master CAUTION lights, on P7, come on.

 


 S 865-021
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-12-00
 ALL  ú ú 01 Page 504 ú Sep 28/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL

 S 035-023
 (9)  
Remove the jumpers from the terminals.

 S 755-024

 (10)
 Make sure the indications stop.

 S 435-025

 (11)
 Connect a jumper wire between the two terminals on each of these switches installed on the No. 1 strut upper spar.

 (a)  
S10195

 (b)  
S10197

 


 S 755-026
 (12) Make sure these indications occur:
 (a)  
The L ENG OVHT light, on P8, comes on.

 (b)  
The EICAS message, L ENG OVHT, shows on the top display.

 (c)  
The EICAS messages L STRUT OH DET 1 and L STRUT OH DET 2 show on the bottom display.

 (d)  
The caution annunciation is heard.

 (e)  
The master CAUTION lights, on P7, come on.


 S 035-027
 (13)
 Remove the jumpers from the terminals.

 S 755-028

 (14)
 Make sure the indications stop.

 S 435-030

 (15)
 Connect a jumper between the two terminals on each of these switches installed on the engine rear mount bulkhead of No. 1 strut.

 (a)  
S10196

 (b)  
S10199

 


 S 755-031
 (16)
 Make sure these indications occur:

 (a)  
The L ENG OVHT light, on P8, comes on.

 (b)  
The EICAS message L ENG OVHT shows on the top display.

 (c)  
The EICAS messages L STRUT OH DET 1 and L STRUT OH DET 2 show on the bottom display.

 (d)  
The caution annunciation is heard.

 

 (17)
 Remove the jumpers from the terminals.

 (18)
 Make sure these indications stop:

 S 865-034

 (19)
 Push and hold the ENG test switch on the pilots aft control stand, P8.


 S 035-032
 S 755-033
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-12-00
 ALL  ú ú 01 Page 505 ú Mar 20/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL

 S 865-065
 (20) Make sure these indications occur:
 (a)  
The L ENG OVHT light comes on (on P8).

 (b)  
The EICAS message L ENG OVHT shows on the top display.

 (c)  
The EICAS messages L STRUT OH DET 1 and L STRUT OH DET 2 show on the bottom display.

 (d)  
The caution annunciation is heard.

 (e)  
The master CAUTION lights, on P7, come on.


 S 755-035
 (21)
 Release the ENG test switch and make sure the indications stop.

 S 865-036

 (22)
 Open these circuit breakers on the P11 panel and attach DO-NOT-CLOSE tags:

 (a)  
11B20, FIRE DETECTION L ENGINE 1

 (b)  
11B21, FIRE DETECTION L ENGINE 2
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 防火 FIRE PROTECTION 1(39)