Detection - Component Index
Figure 101
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-10-00
ALL ú ú 01 Page 101 ú Sep 20/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
FAULT ISOLATION/MAINT MANUAL
M10229 M682
M681
M10427 ELECTRICAL SYSTEM CARD FILE, P50
SEE
CENTER ACCESS, 119BL
M686
M10426
M685
M683
M10400
M10230
M684
M10274
M10275
FIRE DETECTION CARD FILE, P54
M10428
M691 DUCT LEAK AND W/W CONTROL CARD
SEE
ELECTRICAL SYSTEM CARD FILE, P50
DUCT LEAK AND W/W
FIRE CONTROL CARD, M691
Detection - Component Location
Figure 102
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
26-10-00
ALL ú ú 01 Page 102 ú Jun 20/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
DETECTION - INSPECTION/CHECK
____________________________
1. General_______
A. This procedure is an operational check of AFOLTS (Automatic Fire/Overheat Logic/Test System).
TASK 26-10-00-736-064
2. Do a Test for AFOLTS System Check_________________________________
A. References
(1)
AMM 24-22-00/201, Electrical Power - Control
(2)
AMM 31-41-00/501, Engine Indication and Crew Alerting System (EICAS)
(3)
AMM 31-51-00/501, Warning System
B. Access
(1)
Location Zones
100 Lower Half of Fuselage
120 BS 396.5 to BS 900.0
200 Upper Half of Fuselage
(2)
Access
119/120 Main Equipment Center
211/212 Flight Compartment Center
C. Prepare for the Check
S 866-001
(1) Supply electrical power (AMM 24-22-00/201).
D. Do a Test for AFOLTS System Check
S 756-002
(1) Make sure these circuit breakers on the pilots' overhead panel, P11, are closed:
中国航空网 www.aero.cn