BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757 
MAINTENANCE MANUAL
 (f) The fire bell sounds, on the flight deck aural warning
 speakers.
 (4)  A dual-loop inoperative indication is given by the following:
 (a) The amber FAIL P-RESET switchlight, on the P8 control stand,
 comes on.
 (5)  A single-loop inoperative or alarm signal indication is given by the
 following:
 (a) The appropriate status/maintenance message is displayed on
 EICAS (P2):
 1) L TURB OH DET 1 or 2.
 2) R TURB OH DET 1 or 2.
 (6)  Test circuit failures may not provide an inoperative signal at the
 moment of failure. These inoperative loops can only be detected
 during a system test.
 B.  Test____
 (1)  When a test occurs, the AFOLTS cards send out signals to each loop
 of the detection systems. Returned signals indicate operating
 loops. If any loop is found inoperative, AFOLTS reconfigures that
 system to operate on the remaining loop. If the remaining loop
 sustains an alarm or inoperative condition, then a fire warning or
 fail indication results.
 (2)  Power-up mode:
 (a) Whenever power is first applied, an automatic system self-test
 occurs. All single-loop status/maintenance messages are
 momentarily displayed on EICAS (P2). If any loop is found
 inoperative , then the appropriate loop message remains on
 EICAS display, and the system is reconfigured to the other
 loop. If both loops of a system are found inoperative, then
 the FAIL P-RESET switchlight (on P8) comes on, and EICAS
 displays the advisory message - FIRE/OVHT SYS. Cockpit fire
 warnings will not be initiated by a power-up test.
 (3)  Manual system test:
 (a) When the ENG switch on the fire/overheat test panel (on P8) is
 pressed and held, the engine turbine cooling overheat and strut
 overheat detection systems go through a self-test. All loop
 messages are displayed on EICAS, and after a two-second delay,
 a successful test terminates with all fire and overheat
 indications. The indications for the turbine overheat test
 are:
 1) The red L and R fire switch handles light up, and unlock
 (on P8).
 2) The red L and R fuel control switches light up (on P10).
 3) The red FIRE light comes on (on P1-3).

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-13-00
 ALL  ú ú 01 Page 5 ú Sep 28/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757 MAINTENANCE MANUAL
 4) EICAS displays L and R ENGINE FIRE (warnings).
 5) EICAS displays L TURB OH DET 1 and 2 (maintenance)
 6) EICAS displays R TURB OH DET 1 and 2 (maintenance)
 7) The red master warning lights.
 8) The fire bell sounds on the aural warning speakers.

 (b)  When the ENG switch is released, all messages and indications should clear - except for any inoperative loop messages which will remain on EICAS. The FAIL P-RESET switchlight, and EICAS advisory message - FIRE/OVHT SYS, will also remain on if there is a dual-loop inoperative.
 (4) The manual system test will not invalidate an alarm in progress.
 C. Control
_______
 (1)  Turn-on procedure:
 (a)  
Provide electrical power (Ref 24-22-00).

 (b)  
Check that the following overhead panel P11 circuit breakers are closed: 1) 11B20, FIRE DETECTION L ENGINE 1 2) 11B21, FIRE DETECTION L ENGINE 2 3) 11B22, FIRE DETECTION R ENGINE 1 4) 11B23, FIRE DETECTION R ENGINE 2 5) 11J26, FIRE DET ALTN PWR ENGINE LEFT 6) 11J27, FIRE DET ALTN PWR ENGINE RIGHT


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 26-13-00
 ALL  ú ú 01 Page 6 ú Jan 20/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
FAULT ISOLATION/MAINT MANUAL

ENGINE TURBINE COOLING OVERHEAT DETECTION SYSTEM

* SEE THE WDM EQUIPMENT LIST
 