Loss of the input bus from the SDAC 1 to the DMC 2
1. Possible Causes
_______________
- DMC-2 (1WT2)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-60-00-740-002 EIS Input Test
AMM 31-60-00-740-007 GROUND SCANNING Test of the DMC
AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
ASM 31-54/04
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU SDAC/1/SPLY 3WV F04
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
B. Test Do the EIS input test (EIS 2) (Ref. AMM TASK 31-60-00-740-002).
R **ON A/C 401-499,
B. Test Do the Ground Scanning Test of the DMC (Ref. AMM TASK 31-60-00-740-007).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-63-00∞∞∞∞∞∞∞∞∞∞Page B219
Aug 01/05 CES 4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. If the test gives the maintenance message:
DMC2 : NO SDAC1 DATA
- replace the DMC-2 (1WT2), (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the DMC 2 (1WT2) pins AA/10C, 10D to the first terminal block , (Ref. ASM 31-54/04).
R **ON A/C 401-499,
A. If the test gives the maintenance message:
SDAC1(1WV1)/DMC2(1WT2)
- replace the DMC-2 (1WT2), (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the DMC 2 (1WT2) pins AD/6G, 6H to the first terminal block , (Ref. ASM 31-54/04).
**ON A/C ALL
B. Do the test given in Para. 3.B.
Loss of the input bus from the SDAC 1 to the DMC 3
1. Possible Causes
_______________
- DMC-3 (1WT3)
- wiring from the SDAC1 (1WV1) to the DMC3 (1WT3)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-60-00-740-002 EIS Input Test
AMM 31-60-00-740-007 GROUND SCANNING Test of the DMC
AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
ASM 31-54/04
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU SDAC/1/SPLY 3WV F04
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
B. Test Do the EIS input test (EIS 3) (Ref. AMM TASK 31-60-00-740-002).
R **ON A/C 401-499,
B. Test Do the Ground Scanning Test of the DMC (Ref. AMM TASK 31-60-00-740-007).
4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. If the test gives the maintenance message:
DMC3 : NO SDAC1 DATA
- replace the DMC-3 (1WT3), (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the SDAC1 (1WV1) to the DMC3 (1WT3), (Ref. ASM 31-54/04).
R **ON A/C 401-499,
A. If the test gives the maintenance message:
SDAC1(1WV1)/DMC3(1WT3)
- replace the DMC-3 (1WT3), (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 2(87)