- do a check and repair the wiring from the ADIRU3(1FP3) pins AB-70C/11C to the DMC1(1WT1) pins AA/2E/2F (Ref. ASM 31-62/01).
(2) If the fault continues:
- replace the ADIRU3 (1FP3) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
**ON A/C ALL
B. Do the test given in Para. 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-63-00∞∞∞∞∞∞∞∞∞∞Page 270
Aug 01/05 CES Loss of the RA 1 Output Bus by the DMC 1
1. Possible Causes
_______________
- DMC-1 (1WT1)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-60-00-740-002 EIS Input Test
AMM 31-60-00-740-007 GROUND SCANNING Test of the DMC
AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
ASM 31-62/01
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
121VU COM NAV/RAD ALTM/1 1SA1 K11
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
B. Test
Do the EIS input test (Ref. AMM TASK 31-60-00-740-002).
R **ON A/C 401-499,
B. Test Do the Ground Scanning Test of the DMC (Ref. AMM TASK 31-60-00-740-007).
4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. If the test gives the maintenance message DMC 1 : NO RA 1 DATA:
- replace the DMC-1 (1WT1) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the DMC 1 (1WT1) pins AA/5A, 5B to the first terminal block (Ref. ASM 31-62/01).
R **ON A/C 401-499,
A. If the test gives the maintenance message RA1(2SA1)/DMC1(1WT1):
- replace the DMC-1 (1WT1) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the DMC 1 (1WT1) pins AA/7C, 7D to the first terminal block (Ref. ASM 31-62/01).
**ON A/C ALL
B. Do the test given in Para. 3.B.
Loss of the RA 2 Output Bus by the DMC 1
1. Possible Causes
_______________
- DMC-1 (1WT1)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-60-00-740-002 EIS Input Test
AMM 31-60-00-740-007 GROUND SCANNING Test of the DMC
AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
ASM 31-62/01
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
121VU COM NAV/RAD ALTM/2 1SA2 K12
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
B. Test
Do the EIS input test (Ref. AMM TASK 31-60-00-740-002).
R **ON A/C 401-499,
B. Test Do the Ground Scanning Test of the DMC (Ref. AMM TASK 31-60-00-740-007).
4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. If the test gives the maintenance message DMC 1 : NO RA 2 DATA:
- replace the DMC-1 (1WT1) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the DMC 1 (1WT1) pins AA/5J, 5K to the first terminal block (Ref. ASM 31-62/01).