1. Possible Causes
_______________
- XDCR UNIT-RUDDER POS (42WV)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 27-25-17-000-001 Removal of the Rudder Position Transducer Unit 42WV AMM 27-25-17-400-001 Installation of the Rudder Position Transducer Unit
42WV
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
ASM 31-54/08
3. Fault Confirmation
__________________
A. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message SDAC 1 : RUDDER POS XDCR 42WV:
- do a check for 26VAC at pin A/A of the rudder position transducer unit (42WV) (Ref. ASM 31-54/08).
(1) If there is 26VAC:
- replace the XDCR UNIT-RUDDER POS (42WV) (Ref. AMM TASK 27-25-17-000-001) and (Ref. AMM TASK 27-25-17-400-001).
(2) If there is no 26VAC:
- do a check for a ground signal at pin A/B of the rudder position transducer unit (42WV) (Ref. ASM 31-54/08).
(a) If there is no ground signal:
- repair the wiring between rudder position transducer unit (42WV) pin A/B and the ground terminal (Ref. ASM 31-54/08).
(b) If there is a ground signal:
- do a check of the wiring from rudder position transducer unit (42WV) pin A/A to the first terminal block (Ref. ASM 31-54/08).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page A221
Aug 01/05R CES
1 If there is no continuity:
_
- repair the above wiring.
2 If there is continuity:
_ - replace the XDCR UNIT-RUDDER POS (42WV). a If the fault continues:
_
- do a check and repair the wiring from rudder position transducer unit (42WV) pins A/G, H, D, E to the first terminal block (Ref. ASM 31-54/08).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page A222
Aug 01/05R
CES Loss of the Output Bus 1 of the Zone Temperature Controller by the SDAC 1
1. Possible Causes
_______________
- SDAC-1 (1WV1)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
ASM 31-54/03
3. Fault Confirmation
__________________
A. Test Do the operational test of the central warning systems (SDAC) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message SDAC 1 : NO DATA FROM ECS 1
- replace the SDAC-1 (1WV1) (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the SDAC 1 (1WV1) pins AB/14J, 14K to the first terminal block (Ref. ASM 31-54/03).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-54-00∞∞∞∞∞∞∞∞∞∞Page A223
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 2(8)