- remove the DMC3. (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
- do a check for a ground signal at pin AB/4H of DMC3.
(1) If there is no ground signal:
- replace the SEL SW EIS DMC (18WT).
(a) If there is no ground signal:
- do a check and repair the wiring of the EIS DMC Selector Switch (18WT): pin 4 to the DMC3 pin AB/4H (Ref. ASM 31-68/02).
(2) If there is a ground signal:
- refer to the trouble shooting procedure related to the DMC3 maintenance message.
C. If there is no EFIS Display with EIS DMC Selector Switch (18WT) at CAPT/3 and at F/O/3:
- replace the SEL SW EIS DMC (18WT)
(1) If the fault continues:
- do a check and repair the wiring of the EIS DMC Selector Switch (18WT): pin 1 to ground point (Ref. ASM 31-68/02).
(2) If the fault continues:
- do a check for 115VAC at pin AC/2 of the DMC3 (1WT3) (Ref. ASM 31-61/02).
(a) If there is 115VAC:
- refer to the trouble shooting procedure related to the DMC3 maintenance message.
(b) If there is no 115VAC:
- do a check for a ground signal at pin AC/7 of the DMC3 (1WT3).
1 If there is no ground signal:
_
- repair the wiring from the DMC3 (1WT3) pin AC/7 to the ground terminal.
2 If there is a ground signal:
_ - replace the RELAY-BUS1 TO ESS BUS SWTG, DMC3 (26WT).
a If the fault continues:
_
- replace the C/B-EIS/DMC3/STBY/SPLY (14WT1) . If the fault continues:
* do a check of the wiring from the DMC3 BUS1 to the ESS BUS SWTG relay (26WT):
- pin A2 to DMC3 (1WT3) pin AC/2
- pin A1 to the EIS/DMC3/STBY/SPLY circuit breaker (14WT1)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞31-63-00∞∞∞∞∞∞∞∞∞∞Page B299
Aug 01/05 CES
- pin X2 to the BUS 1XP CTL relay (20XN1)
* repair the wiring which has no continuity.
Loss of the Indication on one CRT (Diagonal)
1. Possible Causes
_______________
- RELAY-TAKEOVER & PRIORITY 1 (47CE1)
- RELAY-TAKEOVER & PRIORITY 2 (47CE2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
PC 279208
3. Fault Confirmation
__________________
A. Not applicable, the fault is intermittent.
4. Fault Isolation
_______________
A. If diagonal is shown on one CRT during action on takeover and priority pushbutton switch:
- replace RELAY-TAKEOVER & PRIORITY 1 (47CE1) or RELAY-TAKEOVER & PRIORITY 2 (47CE2) (Ref. PC 279208).
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
TASK 31-63-00-810-971
EIS - Loss of the Red Gun
1. Possible Causes
_______________
- DU-ECAM, UPPER (4WT1)
- DU-ECAM, LOWER (4WT2)
- ND-CAPT (3WT1)
- ND-F/O (3WT2)
- PFD-CAPT (2WT1)
- PFD-F/O (2WT2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
AMM 31-60-00-860-001 EIS Start Procedure
AMM 31-60-00-860-002 EIS Stop Procedure
AMM 31-63-22-000-001 Removal of the Display Unit
(2WT1,2WT2,3WT1,3WT2,4WT1,4WT2)
AMM 31-63-22-400-001 Installation of the Display Unit
(2WT1,2WT2,3WT1,3WT2,4WT1,4WT2)
3. Fault Confirmation
__________________
A. Do the operational test that follows:
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
(2) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(3) Do a check of the colors displayed on the EIS Display Units.
4. Fault Isolation
_______________