3. Fault Confirmation
__________________
A. Test
Do the EIS input test (Ref. AMM TASK 31-60-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message:
DMC2: PROGRAM PIN
or
DMC2: POSITION PIN
- do a check for ground signals at DMC2 (1WT2) connector AB (Ref. AWM 31-61-29).
(1) If the wiring is incorrect:
- repair the wiring.
(2) If the wiring is correct:
- replace the DMC-2 (1WT2) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-63-81∞∞∞∞∞∞∞∞∞∞Page 201
Nov 01/03 CES Loss of F/O PFD or F/O ND or Lower ECAM DU Image
1. Possible Causes
_______________
- PFD-F/O (2WT2)
- DMC-2 (1WT2)
- ND-F/O (3WT2)
- DU-ECAM, LOWER (4WT2)
- wiring from F/O PFD (2WT2) to DMC2 (1WT2)
- wiring from F/O ND (3WT2) to DMC2 (1WT2)
- wiring from lower ECAM DU (4WT2) to DMC2 (1WT2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-60-00-740-002 EIS Input Test
AMM 31-63-22-000-001 Removal of the Display Unit
(2WT1,2WT2,3WT1,3WT2,4WT1,4WT2)
AMM 31-63-22-400-001 Installation of the Display Unit
(2WT1,2WT2,3WT1,3WT2,4WT1,4WT2)
AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
ASM 31-61/04
3. Fault Confirmation
__________________
A. Test
Do the EIS input test (Ref. AMM TASK 31-60-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message DMC2 : RECONF WIRING and there is no F/O PFD image:
- replace the PFD-F/O (2WT2) (Ref. AMM TASK 31-63-22-000-001) and (Ref. AMM TASK 31-63-22-400-001).
(1) If the fault continues:
- do a check of the wiring from F/O PFD (2WT2) to DMC2 (1WT2) from pins AA/35, 36 to pins AB/9B, 9C .
(a) If there is no continuity:
- repair the wiring.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-63-81∞∞∞∞∞∞∞∞∞∞Page 202
Feb 01/98 CES (b) If there is continuity:
- do a check and repair the wiring from F/O PFD (2WT2) to DMC2 (1WT2) from pins AA/38, 39 to pins AB/9D, 9E (Ref. ASM 31-61/04).
1 If the fault continues:
_
- replace the DMC-2 (1WT2) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
B. If the test gives the maintenance message DMC2 : RECONF WIRING and there is no F/O ND image:
- replace the ND-F/O (3WT2) (Ref. AMM TASK 31-63-22-000-001) and (Ref. AMM TASK 31-63-22-400-001).
(1) If the fault continues:
- do a check of the wiring from F/O ND (3WT2) to DMC2 (1WT2) from pins AA/35, 36 to pins AB/10B, 10C .
(a) If there is no continuity:
- repair the wiring:
(b) If there is continuity:
- do a check and repair the wiring from F/O ND (3WT2) to DMC2 (1WT2) from pins AA/38, 39 to pins AB/10D, 10E (Ref. ASM 31-61/04).
1 If the fault continues:
_
- replace the DMC-2 (1WT2) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
C. If the test gives the maintenance message DMC1 : RECONF WIRING and there is no lower ECAM DU image:
- replace the DU-ECAM, LOWER (4WT2) (Ref. AMM TASK 31-63-22-000-001) and (Ref. AMM TASK 31-63-22-400-001).
(1) If the fault continues:
- do a check of the wiring from lower ECAM DU (4WT2) to DMC2 (1WT2) from pins AA/35, 36 to pins AB/11B, 11C .
(a) If there is no continuity:
- repair the wiring.
(b) If there is continuity:
- do a check and repair the wiring from lower ECAM DU (4WT2) to DMC2 (1WT2) from pins AA/38, 39 to pins AB/10D, 10E (Ref. ASM 31-61/04).
中国航空网 www.aero.cn