1. Possible Causes
_______________
- DMC-2 (1WT2)
- FWC-2 (1WW2)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-53-34-000-001 Removal of the Flight Warning Computer (FWC) (1WW1,1WW2) AMM 31-53-34-400-001 Installation of the Flight Warning Computer (FWC)
(1WW1,1WW2)
AMM 31-60-00-740-002 EIS Input Test
AMM 31-60-00-740-007 GROUND SCANNING Test of the DMC
AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
ASM 31-52/05
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
121VU EIS/FWC2/SPLY 2WW Q07
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
B. Test Do the EIS input test (system 2) (Ref. AMM TASK 31-60-00-740-002).
R **ON A/C 401-499,
B. Test Do the Ground Scanning Test of the DMC (Ref. AMM TASK 31-60-00-740-007).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞31-63-00∞∞∞∞∞∞∞∞∞∞Page B289
Aug 01/05 CES 4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. If the test gives the maintenance message:
DMC2: NO FWC2 DATA
- replace the DMC-2 (1WT2) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(1) If the fault continues:
- replace the FWC-2 (1WW2) (Ref. AMM TASK 31-53-34-000-001) and (Ref. AMM TASK 31-53-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring from DMC2 (1WT2) pins AA/10J, 10K to the FWC2 (1WW2) (Ref. ASM 31-52/05).
R **ON A/C 401-499,
A. If the test gives the maintenance message:
FWC2(1WW2) BUSX DATA/DMC2(1WT2)
- replace the DMC-2 (1WT2) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(1) If the fault continues:
- replace the FWC-2 (1WW2) (Ref. AMM TASK 31-53-34-000-001) and (Ref. AMM TASK 31-53-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring from DMC2 (1WT2) pins AD/8C, 8D to the FWC2 (1WW2) (Ref. ASM 31-52/05).
**ON A/C ALL
B. Do the test given in Para. 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞31-63-00∞∞∞∞∞∞∞∞∞∞Page B290
Aug 01/05 CES Loss of the ARINC 429 FWC2 Input of the DMC1
1. Possible Causes
_______________
- DMC-1 (1WT1)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-60-00-740-002 EIS Input Test
AMM 31-60-00-740-007 GROUND SCANNING Test of the DMC
AMM 31-63-34-000-001 Removal of the DMC (1WT1,1WT2,1WT3)
AMM 31-63-34-400-001 Installation of the DMC (1WT1,1WT2,1WT3)
ASM 31-52/05
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 指示和记录系统 2(106)