Failure of the ECAM Control Panel
1. Possible Causes
_______________
- CTL PNL-ECAM (6WT)
- wiring from the circuit breaker (15WT) to the ECAM control panel (6WT)
- C/B-EIS/ECAM/CTL/PNL (15WT)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 31-61-12-000-001 Removal of the ECAM Control Panel (6WT)
AMM 31-61-12-400-001 Installation of the ECAM Control Panel (6WT)
ASM 31-61/02
3. Fault Confirmation
__________________
A. Test Do the operational test of the central warning systems (FWC) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ECP:
- do a check of the status of the circuit breaker (15WT)
(1) If the circuit breaker (15WT) is closed:
- replace the CTL PNL-ECAM (6WT), (Ref. AMM TASK 31-61-12-000-001) and (Ref. AMM TASK 31-61-12-400-001).
(a) If the fault continues:
- do a check of the wiring from the circuit breaker (15WT) to the ECAM control panel (6WT) pin B/S and A/S , (Ref. ASM 31-61/02).
1 If there is no continuity:
_
- repair the wiring.
2 If there is continuity:
_
- replace the C/B-EIS/ECAM/CTL/PNL (15WT) (2) If the circuit breaker (15WT) is open:
- close the circuit breaker.
(a) If the circuit breaker trips:
- replace the CTL PNL-ECAM (6WT).
(b) If the circuit breaker stays closed and the fault continues:
1_ If the fault continues:
- do a check and repair for a short to ground the wiring
between the circuit breaker (15WT) and the ECAM control
panel (6WT).
- replace the CTL PNL-ECAM (6WT).
B. Do the test given in Para. 3.
Loss of the input bus 1 by the ECAM control panel
1. Possible Causes
_______________
- CTL PNL-ECAM (6WT)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 31-61-12-000-001 Removal of the ECAM Control Panel (6WT)
AMM 31-61-12-400-001 Installation of the ECAM Control Panel (6WT)
ASM 31-61/03
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU EIS/ECAM/CTL/PNL 15WT E12 49VU EIS/DMC1/SPLY 10WT1 E11 49VU EIS/DMC1/SWTG 21WT1 E09 49VU EIS/DMC3/SWTG 21WT3 E07
121VU EIS/DMC3/SPLY 10WT3 Q09
B. Test Do the operational test of the central warning systems (FWC) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ECP : NO DATA FROM DMC1 or 3:
- replace the CTL PNL-ECAM (6WT) (Ref. AMM TASK 31-61-12-000-001) and (Ref. AMM TASK 31-61-12-400-001).
(1) If the fault continues:
- do a check and repair the wiring from ECAM control panel (6WT) pins B/G,H to the first terminal block (Ref. ASM 31-61/03).
B. Do the test given in Para. 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞31-61-00∞∞∞∞∞∞∞∞∞∞Page 204
Feb 01/98 CES Loss of the input bus 2 by the ECAM control panel
1. Possible Causes
_______________
- CTL PNL-ECAM (6WT)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 31-61-12-000-001 Removal of the ECAM Control Panel (6WT)