• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 18:28来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 301-399, ∞∞30-71-00∞∞∞∞∞∞∞∞∞∞Page 306
 May 01/05 CES


 Waste-Water Ice Protection - Electrical Schematic R Figure 301C (SHEET 2)
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 301-399, ∞∞30-71-00∞∞∞∞∞∞∞∞∞∞Page 307
 May 01/05 CESR Waste-Water Ice Protection - Electrical Schematic R Figure 302


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 051-051, ∞∞30-71-00∞∞∞∞∞∞∞∞∞∞Page 308
 May 01/05 CES


 WATER SERVICING PANELS HEATING - FAULT ISOLATION PROCEDURES
___________________________________________________________
 TASK 30-72-00-810-801
 Failure of heated Fill/Drain Nipple
 1. Possible Causes
_______________
 - THERMOSTAT-FILL AND DRAIN NIPPLE (12DV)

 - NIPPLE-FILL AND DRAIN (11DV)

 - wiring


 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific cooling spray
 No specific access platform 2 m (6 ft. 7 in.)
 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power AMM 30-72-52-000-001 Removal of the Heated Fill/Drain Nipple 11DV and/or Overflow Nipple 13DV AMM 30-72-52-400-001 Installation of the Heated Fill/Drain Nipple 11DV
 and/or Overflow Nipple 13DV
 AMM 52-30-00-860-006 Open the Bulk Cargo-Compartment Door
 ASM 30-72/01

 3. Fault Confirmation
__________________
 A. Aircraft Maintenance Configuration
 (1) Energize the aircraft electrical circuits
 (Ref. AMM TASK 24-41-00-861-002).


 (2) Put an access platform in position at the potable-water service panel 171AL.

 (3) Open the BULK cargo-compartment door (Ref. AMM TASK 52-30-00-860-006).

 (4) Open the sidewall panel 161DW to get access to the thermostat 12DV.


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-72-00∞∞∞∞∞∞∞∞∞∞Page 201
 Feb 01/98 CES B. Make sure that this(these) circuit breaker(s) is(are) closed:


 -------------------------------------------------------------------------------
PANEL SERVICE  IDENT. LOCATION
 -------------------------------------------------------------------------------
2001VU WATER SERVICE PANEL HEATER  15DV E08
 **ON A/C 051-051,
 B. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------
PANEL SERVICE  IDENT. LOCATION
 -------------------------------------------------------------------------------
2001VU ICE PROT -SERVICE PANEL HTR  15DV E08
R  **ON A/C 151-199, 301-399, 401-499,
 B. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------
PANEL SERVICE  IDENT. LOCATION
 -------------------------------------------------------------------------------
2001VU HEATER SERV PANEL  15DV D01
 **ON A/C ALL
 C. Do this test:
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. At the potable-water service  At the potable-water service panel
 panel (inboard side): (outboard side):

 - apply cooling spray on and  - make sure that the heated fill/drain around the thermostat 12DV for nipple 11DV becomes warm. at least 10 s.

 4. Fault Isolation
_______________

 A. If the heated fill/drain nipple 11DV stays cold:
 - replace the THERMOSTAT-FILL AND DRAIN NIPPLE (12DV) (Ref. AMM TASK 30-72-52-000-001) and (Ref. AMM TASK 30-72-52-400-001).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 除冰和排雨(98)