1. Possible Causes
_______________
- PROBE-R STATIC, 3 (8DA3)
- PHC-3 (6DA3)
- wiring from the PHC 3 (6DA3) to the R static probe 3 (8DA3)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 30-31-00-710-001 Operational Test of the Probe Ice Protection
AMM 30-31-34-000-002 Removal of the Probe Heat Computer (PHC)
(6DA1,6DA2,6DA3)
AMM 30-31-34-400-002 Installation of the Probe Heat Computer (PHC)
(6DA1,6DA2,6DA3)
AMM 34-11-16-000-001 Removal of the Static Probe
(7DA1,7DA2,7DA3,8DA1,8DA2,8DA3)
AMM 34-11-16-400-002 Installation of the Static Probe
(7DA1,7DA2,7DA3,8DA1,8DA2,8DA3)
ASM 30-31/03
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the probe ice protection (Ref. AMM TASK 30-31-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message R STATIC PROBE 8DA3:
- do a check of the resistance between pin 2 and pin 1.
(1) If the resistance is more than 13 ohms (open circuit) or less than 10 ohms (short circuit).
(a) Replace the PROBE-R STATIC, 3 (8DA3), (Ref. AMM TASK 34-11-16-000-001) and (Ref. AMM TASK 34-11-16-400-002).
(2) If the resistance is between 10 ohms and 13 ohms:
(a) Replace the PHC-3 (6DA3), (Ref. AMM TASK 30-31-34-000-002) and (Ref. AMM TASK 30-31-34-400-002).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-31-00∞∞∞∞∞∞∞∞∞∞Page 260
May 01/03R CES
(b) If the fault continues:
- do a check and repair the wiring from the PHC 3 (6DA3) to the R static probe 3 (8DA3) pin A/E to pin 2 (Ref. ASM 30-31/03).
B. Do the operational test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-31-00∞∞∞∞∞∞∞∞∞∞Page 261
May 01/03R
CES Failure of the Angle of Attack Sensor (PHC 3)
1. Possible Causes
_______________
- SENSOR-ANGLE OF ATTACK, 3 (3FP3)
- PHC-3 (6DA3)
- wiring from the PHC 3 (6DA3) to the angle of attack sensor 3 (3FP3)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 30-31-00-710-001 Operational Test of the Probe Ice Protection AMM 30-31-34-000-002 Removal of the Probe Heat Computer (PHC) (6DA1,6DA2,6DA3) AMM 30-31-34-400-002 Installation of the Probe Heat Computer (PHC) (6DA1,6DA2,6DA3) AMM 34-11-19-000-001 Removal of the Angle of Attack Sensor (3FP1, 3FP2, 3FP3) AMM 34-11-19-400-001 Installation of the Angle of Attack Sensor (3FP1, 3FP2, 3FP3) ASM 30-31/03
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the probe ice protection (Ref. AMM TASK 30-31-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message AOA SENSOR 3FP3:
- disconnect the connector from the angle of attack sensor 3 (3FP3) and do a check of the resistance between pin A/<J and pin A/<G.
(1) If the resistance is more than 110 ohms (open circuit) or less than 20 ohms (short circuit):
(a) Replace the SENSOR-ANGLE OF ATTACK, 3 (3FP3) (Ref. AMM TASK 34-11-19-000-001) and (Ref. AMM TASK 34-11-19-400-001).
(2) If the resistance is between 20 ohms and 110 ohms:
(a) Replace the PHC-3 (6DA3) (Ref. AMM TASK 30-31-34-000-002) and (Ref. AMM TASK 30-31-34-400-002).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-31-00∞∞∞∞∞∞∞∞∞∞Page 262