Loss of the Temperature Sensor of the Right Sliding Window
1. Possible Causes
_______________
- WINDOW-SLIDING, R (8DG2)
- WHC-2 (2DG2)
- wiring from the WHC 2 (2DG2) to the R sliding window (8DG2)
- wiring from the WHC2 (2DG2) to the R sliding window (8DG2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 30-42-00-710-001 Operational Test of the Windshield Anti-Icing and Defogging AMM 30-42-34-000-001 Removal of the Window Heat Computer (WHC) (2DG1,2DG2). AMM 30-42-34-400-001 Installation of the Window Heat Computer (WHC)
(2DG1,2DG2).
AMM 56-12-11-000-001 Removal of the Sliding Windows
AMM 56-12-11-400-001 Installation of the Sliding Windows
R ASM 30-42/01 ASM 30-42/02
R AWM 30-42-03 AWM 30-42-04
**ON A/C ALL
Post SB 30-1044 For A/C 215-220,224-224,
30-42-00-991-007 Fig. 202
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
R Post SB 30-1044 For A/C 215-220,224-224,
30-42-00-991-004 Fig. 209
R **ON A/C 301-399, 401-499,
R 30-42-00-991-004-A Fig. 209A
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-42-00∞∞∞∞∞∞∞∞∞∞Page 252
Aug 01/05 CES 3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the windshield anti-icing and defogging (Ref. AMM TASK 30-42-00-710-001).
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
122VU ANTI ICE/WHC/2 5DG2 W13
**ON A/C ALL
Post SB 30-1044 For A/C 215-220,224-224,
B. If the test gives the maintenance message R SLIDING WINDOW SENSOR associated with ECAM message ANTI-ICE R WINDSHIELD, or ANTI-ICE R WINDOW:
(1) If the WHC2 PN 6664287 is installed and if the ECAM warning is triggered on ground with OAT greater than 40 deg.C or if the cockpit window/windshield is directly heading to the sun and air conditioning packs off: - operate the air conditioning packs
- after 5 minutes, open and close circuit breaker 5DG2 to do a reset of the WHC2.
(a) If the fault continues:
- refer to Para. C.
(2) If the WHC2 PN 6664287 is not installed:
- refer to Para. C.
**ON A/C 215-220, 224-224,
C. If the test gives the maintenance message R SLIDING WINDOW SENSOR:
- disconnect the connector from the R sliding window (8DG2) and do a check of the resistance between pin A/C and pin A/D. (Ref. Fig. 202/TASK 30-42-00-991-007, 209/TASK 30-42-00-991-004)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-42-00∞∞∞∞∞∞∞∞∞∞Page 253
Aug 01/05R
CES
R Sliding Window Electrical Connector
Figure 209/TASK 30-42-00-991-004
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞30-42-00∞∞∞∞∞∞∞∞∞∞Page 254
201-299, Aug 01/05 CES
(1) If the resistance is more than 715 ohms (open circuit) (OAT more than 40 deg. C) or less than 370 ohms (short circuit):
- do a check of the resistance of the spare sensor between pins A/E and A/F for correct value. (Ref. Fig. 202/TASK 30-42-00-991-007)
(a) If the resistance of the spare sensor is between 370 ohms and 715 ohms:
- connect pins B/W and B/X of the WHC2 (2DG2) to pins A/E and A/F of the spare sensor (Ref. AWM 30-42-04) and (Ref. ASM 30-42/02).
(b) If the resistance of the spare sensor is more than 715 ohms or less than 370 ohms:
- replace the WINDOW-SLIDING, R (8DG2), (Ref. AMM TASK 56-12-11-000-001) and (Ref. AMM TASK 56-12-11-400-001).
(c) If the fault continues:
- replace the WHC-2 (2DG2), (Ref. AMM TASK 30-42-34-000-001) (Ref. AMM TASK 30-42-34-400-001).
(d) If the fault continues:
- do a check and repair the wiring from the WHC 2 (2DG2) to the R sliding window (8DG2) pins B/W and B/X to pins A/D and A/C and pins B/W and B/X to pins A/E and A/F.