 (a) If the circuit breakers trip again:
 - replace the WHC-2 (2DG2).
 1 If the fault continues:
_
 - do a check for a short to ground at the wiring between the WHC 2 pin A/B and the circuit breaker (1DG2) and at the wiring between the WHC 2 pin B/G and the circuit breaker (4DG2).
 a If there is a short to ground:
_ - repair the related wiring.
 b If there is no short to ground:
_
 - replace the C/B-ANTI ICE/R/WSHLD (1DG2) and/or the C/B-ANTI ICE/WINDOWS/R (4DG2).
 (b) If the circuit breakers stay closed and the fault continues:
 - replace the WHC-2 (2DG2).
 C. Do the operational test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-42-00∞∞∞∞∞∞∞∞∞∞Page 225
 Feb 01/03R
 CES  Loss of the Temperature Sensor of the Left Sliding Window


 1. Possible Causes
_______________
 - WINDOW-SLIDING, L (8DG1)

 - WHC-1 (2DG1)

 - wiring from the WHC 1 (2DG1) to the L sliding window (8DG1)

 - wiring from the WHC1 (2DG1) to the L sliding window (8DG1)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 30-42-00-710-001 Operational Test of the Windshield Anti-Icing and Defogging AMM 30-42-34-000-001 Removal of the Window Heat Computer (WHC) (2DG1,2DG2). AMM 30-42-34-400-001 Installation of the Window Heat Computer (WHC)
 (2DG1,2DG2).
 AMM 56-12-11-000-001 Removal of the Sliding Windows
 AMM 56-12-11-400-001 Installation of the Sliding Windows
 ASM 30-42/01
 AWM 30-42-03

 **ON A/C ALL
 Post SB 30-1044 For A/C 215-220,224-224,
 30-42-00-991-007 Fig. 202
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
R Post SB 30-1044 For A/C 215-220,224-224,
 30-42-00-991-003 Fig. 205
R **ON A/C 301-399, 401-499,
R 30-42-00-991-003-A Fig. 205A
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-42-00∞∞∞∞∞∞∞∞∞∞Page 226
 Aug 01/05 CES 3. Fault Confirmation


__________________
 A. Test
 (1) Do the operational test of the windshield anti-icing and defogging (Ref. AMM TASK 30-42-00-710-001).
 4. Fault Isolation
_______________
 A. Table of the circuit breakers used in this procedure:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
122VU ANTI ICE/WHC/1 5DG1 X13
 **ON A/C ALL
 Post SB 30-1044 For A/C 215-220,224-224,
 B. If the test gives the maintenance message L SLIDING WINDOW SENSOR associated with ECAM message ANTI-ICE L WINDSHIELD, or ANTI-ICE L WINDOW:
 (1) If the WHC1 PN 6664287 is installed and if the ECAM warning is triggered on ground with OAT greater than 40 deg.C or if the cockpit window/windshield is directly heading to the sun and air conditioning packs off: - operate the air conditioning packs

 - after 5 minutes, open and close circuit breaker 5DG1 to do a reset of the WHC1.
 (a) If the fault continues:
 - refer to Para. C.

 (2) If the WHC1 PN 6664287 is not installed:


 - refer to Para. C.
 **ON A/C 215-220, 224-224,
 C. If the test gives the maintenance message L SLIDING WINDOW SENSOR:
 - disconnect the connector from the L sliding window (8DG1) and do a check of the resistance between pins A/C and A/D. (Ref. Fig. 202/TASK 30-42-00-991-007, 205/TASK 30-42-00-991-003)
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-42-00∞∞∞∞∞∞∞∞∞∞Page 227
 Aug 01/05R
 CES


 L Sliding Window Electrical Connector
 Figure 205/TASK 30-42-00-991-003

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞30-42-00∞∞∞∞∞∞∞∞∞∞Page 228
 201-299, Aug 01/05 CES


 (1) If the resistance is more than 715 ohms (open circuit) or less than 370 ohms (short circuit):
 