- the P/BSW (3DL) and the relay (5DL)
- the relay (9DL) and the valves (9DL) and (10DL)
- the valve (9DL) and the valve (10DL)
- the relay (5DL) and the relay (6DL)
- the relay (6DL) and the relay (7DL).
NOTE : More information about the relays can be found in the Task
____ Supporting Data (Ref. TSM 30-11-00 P.Block 301).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-11-00∞∞∞∞∞∞∞∞∞∞Page 215
Aug 01/05R CES
(a) Make sure that the circuit breaker (2DL) is closed (Ref. ASM 30-11/01).
(b) Do the test in Para. 3.A.
- if the fault continues, do the next step.
(2) Do a check of the C/B ANTI ICE/WING/CTL (2DL).
(a) If the check is unsatisfactory, replace the circuit breaker (2DL).
(b) Do the fault confirmation in Para. 3.A.
- if the fault continues, do the next step.
(3) Do a check of the Diode 1160VD.
(a) If the check is unsatisfactory, replace the diode.
(b) Do the fault confirmation in Para. 3.A.
WING ICE PROTECTION - TASK SUPPORTING DATA
__________________________________________
R 1. Table of Relay Sets.
____________________
A. The relay configurations that follow are valid for their aplicable
diagram. R FIGURE 301 - Wing Anti-ice Not Selected In Air R (A/C Power On, P/BSW 3DL Not Operated, No Faults)
R If a fault occurs: any discrepency of 5DL,6DL,9DL,10DL. or if a wiring fault removes the 28VDC from the coil of TDL. TDL de-energizes, to cause 4LP/11LP to energize. FAULT lamp comes on.
R FIGURE 302 - Wing Anti-ice Selected In Air R (A/C Power On, P/BSW 3DL Operated, No Faults) R
If a fault occurs:
Any discrepency of 6DL,9DL,10DL, or a
wiring fault ,will remove the 28VDC
from the coil of 7DL.
TDL de-energizes to cause 4LP/11LP
to energize. FAULT lamp comes on.
FIN STATE
1DL Closed
2DL Closed
3DL Open
4DL De-energized
5DL De-energized
6DL De-energized
7DL Energized
9DL De-energized
valve closed 10DL De-energized valve closed 4LP De-energized
FAULT lamp off 11LP De-energized FAULT lamp off
FIN STATE
1DL Closed
3DL Closed
4DL Energized
after 30 secs5DL Energized 6DL Energized 7DL Energized 9DL Energized
valve open 10DL Energized valve open 4LP De-energized FAULT lamp Off 11LP De-energized FAULT lamp off
R FIGURE 303 - Wing Anti-ice Test Selected On Ground
R (30 Seconds Delay Not Expired, P/BSW 3DL Operated)
R FIN STATE
If a fault occurs: 1DL Closed
Any discrepency of 6DL, 9DL,10DL,or a 2DL Closed
wiring fault removes 28VDC from the coil 3DL Closed
of 7DL. 7DL de-energizes,to cause 4LP/ 4DL De-energized
11LP to energize. FAULT lamp comes on. 5DL Energized
6DL Energized
7DL Energized
9DL Energized
valve open
10DL Energized
valve open
4LP De-energized
FAULT lamp on
11LP De-energized
FAULT lamp on
R FIGURE 304 - Wing Anti-ice Test Selected On Ground
R (30 Seconds Delay Expired, P/BSW 3DL Not Released)
R FIN STATE
If a fault occurs: 1DL Closed
Any discrepency of 5DL,6DL,9DL,10DL, 2DL Closed
or a wiring fault, removes 28VDC from 3DL Closed
the coil of 7DL. 7DL de-energizes to 4DL Energized
cause 4LP/11LP to energize. 5DL De-energized
FAULT lamp comes on. 6DL De-energized
7DL Energized
9DL De-energized
valves closed
10DL De-energized
valves closed
4LP De-energized
FAULT lamp off
11LP De-energized
FAULT lamp off
Wing Anti-ice Not Selected In Air (A/C Power On, P/BSW 3DL Not Operated, No
Faults)