R Do the operational test of the ice detection system (Ref. AMM TASK 30-81-R 00-710-001).
R 4. Fault Isolation
_______________ R A. Table of the circuit breakers used in this procedure: R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION R -------------------------------------------------------------------------------R C/B NOT APPLICABLE
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-81-00∞∞∞∞∞∞∞∞∞∞Page 201
Aug 01/05 CES
R B. If the test gives the maintenance message ICE DETECTOR 1 AND ICE DETECTOR
R 2:
R - do a check of the status of the circuit breakers (4DD1, 4DD2).
R (1) If these circuit breakers are closed:
R - do a check for 115VAC at pin A/1 of the L ice detector (2DD1) and
R the R ice detector (2DD2).
R (a) If there is 115VAC:
R - replace the DET-ICE, L (2DD1) and the DET-ICE, R (2DD2) (Ref.
R AMM TASK 30-81-31-000-001) and (Ref. AMM TASK 30-81-31-400-R 001).
R (b) If there is no 115VAC:
R - do a check for a ground signal at pin A/7 of the L ice detector
R (2DD1) and pin A/7 of the R ice detector (2DD2).
R 1_ If there is no ground signal:
R - repair the wiring between pin A/7 of the L ice detector and
R the ground terminal and wiring between pin A/7 of the R ice
R detector and the ground terminal.
R 2_ If there is a ground signal:
R - do a check of the wiring between pin A/1 of the L ice
R detector and the circuit breaker (4DD1) and the wiring
R between pin A/1 of the R ice detector and the circuit
R breaker (4DD2).
R a_ If there is no continuity:
R - repair the above wiring.
R b_ If there is continuity:
R - replace the circuit breaker (4DD1) and the circuit
R breaker (4DD2).
R (2) If these circuit breakers are open:
R - close the circuit breakers.
R (a) If the circuit breakers trip:
R - replace the DET-ICE, L (2DD1) and the DET-ICE, R (2DD2).
R 1_ If the fault continues:
R - do a check for a short to ground at the wiring between pin
R A/1 of the L ice detector and the circuit breaker (4DD1) and
R the wiring between pin A/1 of the R ice detector and the
R circuit breaker (4DD2).
R a_ If there is a short to ground:
R - repair the related wiring.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 401-499, ∞∞30-81-00∞∞∞∞∞∞∞∞∞∞Page 202
Aug 01/05 CES
R b_ If there is no short to ground:
R - replace the C/B-ANTI ICE/ICE DET/L (4DD1) and the
R C/B-ANTI ICE/ICE DET/R (4DD2).
R (b) If these circuit breakers stay closed and the fault continues:
R - replace the DET-ICE, L (2DD1) and the DET-ICE, R (2DD2).
R C. Do the operational test given in Para. 3.
R TASK 30-81-00-810-802
R Loss of the L Ice Detector
R 1. Possible Causes
_______________
R - DET-ICE, L (2DD1)
R - wiring between pin A/7 of the L ice detector and the ground terminal
R - wiring between pin A/1 of the L ice detector and the circuit breaker
R (4DD1)
R - C/B-ANTI ICE/ICE DET/L (4DD1)
R 2. Job Set-up Information
______________________
R A. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R AMM 30-81-00-710-001 Operational Test of the Ice Detection System
R AMM 30-81-31-000-001 Removal of the Ice Detector (2DD1, 2DD2)
R AMM 30-81-31-400-001 Installation of the Ice Detector (2DD1, 2DD2)
R ASM 30-81/01
R 3. Fault Confirmation__________________
R A. Test
R Do the operational test of the ice detection system (Ref. AMM TASK 30-81-R 00-710-001).
R 4. Fault Isolation
_______________
R A. Table of the circuit breakers used in this procedure:
R -------------------------------------------------------------------------------R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R C/B NOT APPLICABLE
R B. If the test gives the maintenance message ICE DETECTOR 1: 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 除冰和排雨(102)