ICE AND RAIN PROTECTION
TABLE OF CONTENTS
_________________
SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY
________ C ____ ___________ Loss of the Temperature Sensor of 252 ALL the Right Sliding Window Loss of the Temperature Sensor of 259 ALL the Right Fixed Window Loss of the Heating System of the 266 ALL Sliding Window Loss of the Heating System of the 269 ALL Fixed Window Loss of the Power Supply of the 272 ALL Side Windows Loss of the Output Discretes 274 ALL (Windshield) Loss of the Output Discretes 275 ALL (Windshield) Loss of the Output Discretes 276 ALL (Windshield) Loss of the Output Discretes (Side 277 ALL Window) Loss of the Command Inputs (ENG 278 ALL 1/ENG 2) Loss of the Command Inputs (ENG 280 ALL 1/ENG 2) Loss of the GND/FLT Information 282 ALL Loss of the GND/FLT Information 284 ALL Loss of the WHC 1 286 ALL Loss of the WHC 2 287 ALL Loss of Power Supply of the WHC 1 288 ALL Loss of Power Supply of the WHC 2 290 ALL Loss of the Heating of the Left 292 ALL and Right Windshields Left Windshield Cracking or Arcing 293 ALL Right Windshield Cracking or 294 ALL Arcing Loss of the Identification of the 295 ALL Left or Right Side by the WHC 1 (2DG1) Loss of the Identification of the 296 ALL Left or Right Side by the WHC 2 (2DG2)
WINDSHIELD RAIN PROTECTION 30-45-00
FAULT ISOLATION PROCEDURES 201 ALL One or Both Wipers Inoperative 201 ALL Only One Wiper Speed is Available 203 ALL The Wiper Does not Go Back 206 ALL Correctly to the Park Position
30-CONTENTS Page 5 Aug 01/05 R CES
ICE AND RAIN PROTECTION
TABLE OF CONTENTS
_________________
SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY
________ C ____ ___________ Loss of the Rain Repellent Fluid 208 001-049, 051-052 (CAPT) 054-056, 058-059
061-099, 101-101 103-149, 151-199 201-299, 301-399 401-499,
Loss of the Rain Repellent Fluid 211 001-049, 051-052
(F/O) 054-056, 058-059 061-099, 101-101 103-149, 151-199 201-299, 301-399 401-499,
DRAIN MAST ICE PROTECTION 30-71-00
FAULT ISOLATION PROCEDURES 201 ALL
FWD Drainmast-Heater Failure 201 ALL
AFT Drainmast-Heater Failure 203 ALL
Control Unit Failure of FWD 205 ALL
Drainmast
Control Unit Failure of AFT 207 ALL
Drainmast
Failure of FWD Waste-Water 209 ALL
Ice-Protection System
Failure of AFT Waste-Water 215 ALL
Ice-Protection System
MID Drainmast-Heater Failure 220 051-051,
Control Unit Failure of MID 222 051-051,
Drainmast
DRAIN MAST ICE PROTECTION 30-71-00
TASK SUPPORTING DATA 301 ALL
WATER SERVICING PANELS HEATING 30-72-00
FAULT ISOLATION PROCEDURES 201 ALL Failure of heated Fill/Drain 201 ALL Nipple Failure of heated Overflow Nipple 204 151-199, 301-399
401-499,
WATER SERVICING PANELS HEATING 30-72-00
TASK SUPPORTING DATA 301 ALL
POTABLE WATER ICE PROTECTION 30-73-00 FAULT ISOLATION PROCEDURES 201 ALL
30-CONTENTS Page 6 Aug 01/05 R CES
ICE AND RAIN PROTECTION
TABLE OF CONTENTS
_________________
SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY________ C ____ ___________ Ice Formation in the Potable Water 201 ALL Lines
POTABLE WATER ICE PROTECTION 30-73-00
TASK SUPPORTING DATA 301 ALL
ICE DETECTION 30-81-00 FAULT ISOLATION PROCEDURES 201 ALL Loss of the L Ice Detector and the 201 401-499, R Ice Detector Loss of the L Ice Detector 204 401-499, Loss of the R Ice Detector 206 401-499, Icing Indicator Lighting 208 ALL Inoperative 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 除冰和排雨(5)