and A/F for correct value.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-42-00∞∞∞∞∞∞∞∞∞∞Page 264
Aug 01/05 CES
(a) If the resistance of the spare sensor is between 370 ohms and 715 ohms:
- connect pins B/U and B/V of the WHC2 (2DG2) to pins A/E and A/F of the spare sensor (Ref. AWM 30-42-04) and (Ref. ASM 30-42/02).
(b) If the resistance of the spare sensor is more than 715 ohms or less than 370 ohms:
- replace the WINDOW-FIXED, R (7DG2), (Ref. AMM TASK 56-11-12-000-001) and (Ref. AMM TASK 56-11-12-400-002).
(c) If the fault continues:
- replace the WHC-2 (2DG2), (Ref. AMM TASK 30-42-34-000-001) and (Ref. AMM TASK 30-42-34-400-001).
(d) If the fault continues:
- do a check and repair the wiring from the WHC2 (2DG2) to the R fixed window (7DG2) pins B/U and B/V to pins A/D and A/C and pins B/U and B/V to pins A/E and A/F.
(2) If the resistance is between 370 ohms and 715 ohms:
- replace the WHC-2 (2DG2), (Ref. AMM TASK 30-42-34-000-001) (Ref. AMM TASK 30-42-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring from the WHC2 (2DG2) to the R fixed window (7DG2) pins B/U and B/V to pins A/D and A/C and pins B/U and B/V to pins A/E and A/F.
**ON A/C ALL
D. Do the operational test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞30-42-00∞∞∞∞∞∞∞∞∞∞Page 265
Aug 01/05R
CES Loss of the Heating System of the Sliding Window
1. Possible Causes
_______________
- WINDOW-SLIDING, R (8DG2)
- WHC-2 (2DG2)
- wiring from the WHC 2 (2DG2) to the R sliding window (8DG2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 30-42-00-710-001 Operational Test of the Windshield Anti-Icing and Defogging AMM 30-42-34-000-001 Removal of the Window Heat Computer (WHC) (2DG1,2DG2). AMM 30-42-34-400-001 Installation of the Window Heat Computer (WHC)
(2DG1,2DG2).
AMM 56-12-11-000-001 Removal of the Sliding Windows
AMM 56-12-11-400-001 Installation of the Sliding Windows
ASM 30-42/02
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-212,
30-42-00-991-009 Fig. 207
R **ON A/C 106-149, 213-299, 301-399, 401-499,
30-42-00-991-009-A Fig. 207A
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
30-42-00-991-004 Fig. 209
R **ON A/C 301-399, 401-499,
R 30-42-00-991-004-A Fig. 209AR **ON A/C ALL
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the windshield anti-icing and defogging (Ref. AMM TASK 30-42-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message R SLIDING WINDOW:
- disconnect the connector from the R sliding window (8DG2) and do a check of the resistance between pin A and pin B.
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-212,
(Ref. Fig. 207/TASK 30-42-00-991-009) R **ON A/C 106-149, 213-299, 301-399, 401-499,
(Ref. Fig. 207A/TASK 30-42-00-991-009-A) R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
(Ref. Fig. 209/TASK 30-42-00-991-004) R **ON A/C 301-399, 401-499,
R (Ref. Fig. 209A/TASK 30-42-00-991-004-A) R **ON A/C ALL
R (1) If the resistance is correct:
- replace the WINDOW-SLIDING, R (8DG2), (Ref. AMM TASK 56-12-11-000-001) and (Ref. AMM TASK 56-12-11-400-001).
R (2) If the resistance is not correct:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 除冰和排雨(76)