 NOTE: A power interruption will cause a failure of the
____
 software installation.

 S 862-018
 (2)  
Make sure that the system select switch on the data loader control panel (P11) is set to NORMAL.

 S 862-019

 (3)  
Open this circuit breaker:


 (a)  On the main power distribution panel, P6:
 1) 6L35 FMC DATA BASE

 S 012-020
 (4)  
To open the ADL front cover, turn the cover knob clockwise and pull.

 S 862-021

 (5)  
Push the eject button on the ADL.


 (a)  If a plastic protective disk is ejected from the disk drive, then remove it.
 S 862-022
 (6)  
Close this circuit breaker:

 (a)  On the P6 panel:
 1) 6L35 FMC DATA BASE


 (7)  
Wait until the display shows INSERT DISK #1.


 S 862-023
 NOTE: The display lights and the ADL FAIL light will go on and
____ off while the ADL does a self test. When the self test is complete, the display will show INSERT DISK #1.
 S 862-024
 (8)  Make sure that the circuit breakers are closed for the applicable component or system that will receive the new software.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 20-15-11
 ALL  ú ú 01 Page 213 ú Feb 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 422-025
 (9)  Do these steps at the ADL to install the software:
 NOTE: You must know the correct software part numbers for the
____ component. For the component to be an approved installation, software with the correct part numbers must be installed.
 NOTE: This is a general procedure for software installation.
____ Some components have other steps that are necessary. The software installation task for the component will include all necessary steps.
 (a)  
Set the switch or switches on the data loader control panel to the applicable position for your component or system.

 (b)  
Carefully push the first disk (label up) into the disk drive.


 NOTE: The display will show DISK INSERTED and then VOL:
____ followed by the disk volume label, if there is one. If the destination component is active, the display will then show the file, extension and the percent of the file transfer completed. If there is more than one file, the ADL will install the next file until all files are completed. If the software is on more than one disk, then the display will show CHANGE DISK or INSERT DISK when it is time to put in the subsequent disk.
 NOTE: LOAD IN PROGRESS can show if the component puts the
____ data loader in standby while it does a check of the data.
 TRANSFERRED total number of blocks can show after a file transfer.
 NOTE: If TRANSFER FAIL shows, then the installation is
____ not completed. Open and close the circuit breaker for the component, and start the installation again.
 IF READ/WRITE FAIL shows, then there is a problem with the disk. Open and close the circuit breaker for the component, and start the installation again. If the problem continues, then replace the disk.
 (c)  If CHANGE DISK or INSERT DISK shows on the display, wait approximately 10 seconds and then push the eject button.
 NOTE: The installation can fail if you wait too long
____ before you remove and install disks.
 1) Remove the disk from the disk drive. 2) Put the subsequent disk into the disk drive.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 20-15-11
 ALL  ú ú 01 Page 214 ú Feb 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 3)  If there are more than two disks for the software
 installation, then remove and install disks until the
 display shows that the installation is completed.
 (d)  When the installation is completed, wait approximately 10
 seconds and then push the eject button.
 NOTE:____ COMP, COMPLETE, or LOAD COMPLETE are examples of
 indications for a completed installation.
 