 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 20-15-11
 ALL  ú ú 01 Page 207 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

P11 PANEL
USUAL LOCATION FOR DATA LOADER CONTROL PANEL
SEE B
ALTERNATIVE LOCATION FOR DATA LOADER CONTROL PANEL
SEE B
AIRBORNE DATA
LOADER
SEE A
FLIGHT COMPARTMENT
ADL 
FAIL 
DISPLAY 
EJECT 
BUTTON 
PROG  CHNG  COMP  RDY  XFER  R/W  HRDW  DISK  DISK 
DRIVE  DRIVE 
DISPLAY 
EJECT 
BUTTON  DISK DRIVE 
LIGHT 
DISK  FRONT 
DRIVE  PROG CHNG  DISK CHANGE IS REQUIRED DATA TRANSFER IN PROGRESS  COVER 
COMP  DATA TRANSFER IS COMPLETE 
LIGHT  XFER RDY  DATA TRANSFER FAILURE UNIT READY FOR OPERATION  FRONT 
HRDW R/W  SYSTEM TEST FAILURE UNABLE TO ACCESS DISK DATA  COVER 

AIRBORNE DATA LOADER  AIRBORNE DATA LOADER 
[ALLIED SIGNAL (SUNDSTRAND)]  (TELEDYNE) 
A  A 

On-Airplane Software Installation
Figure 201 (Sheet 1)

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 20-15-11
 ALL  ú ú 01 Page 208 ú Feb 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
L08736
A
747-400 MAINTENANCE MANUAL
NORMALNORMAL

SYSTEM SYSTEM
(EXAMPLE) (EXAMPLE)
SELECT
SELECT SWITCH
SWITCH

B
B
On-Airplane Software Installation Figure 201 (Sheet 2)
L08764
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 20-15-11
 ALL  ú
 ú  01  Page 209
 ú  Feb 18/00 

BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 (b)  PDLs are not Boeing supplied parts. Refer to the data loader supplier for instructions for PDL operation.
 B. References
 (1)  
AMM 24-22-00/201, Control

 C.
Access

 (1)  
Location Zones
 222 Control Cabin, RH


 D.
Allied Signal (Sundstrand) Airborne Data Loader Procedure


 S 862-003
 (1)  The Allied Signal ADL has these status lights:
 (a)  
PROG (In Progress) - shows as software installation occurs.

 (b)  
CHNG (Change) - shows when it is time to install the next disk.

 (c)  
COMP (Complete) - shows when the software installation is completed.

 (d)  
RDY (Ready) - shows when the disk is in the disk drive and the ADL is ready to install the software in the component. 1) If the RDY indication flashes, then the data loader is in

 standby mode while it waits for the component to validate the data.

 (e)  
XFER (Transfer Fail) - shows when the software installation is not completed. Open and close the circuit breaker for the component, and start the installation again.

 (f)  
R/W (Read/Write) - shows when the ADL cannot read or write the data on the disk. Open and close the circuit breaker for the component, and start the installation again. If the problem continues, then replace the disk.

 (g)  
HRDW (Hardware) - shows when the ADL fails the self test.


 S 862-004
 (2)  Supply electrical power (AMM 24-22-00/201).
 (a)  Make sure that the power is not removed while you install software.
 NOTE: A power interruption will cause a failure of the
____
 software installation.

 S 862-005
 (3)  Make sure that the system select switch on the data loader control panel (P11) is set to NORMAL.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 