Examine the unions for silicone seals (see NOTES, Fig. 824).

 S 428-377

 (6)  
Move the union over the tube ends. Center the union on the witness marks or put it in position at the correct insertion depth.


 S 358-378
 WARNING: MAKE SURE YOU MAKE NO PUMP ADJUSTMENT THAT CAN CAUSE THE SWAGE
_______ TOOL HYDRAULIC PRESSURE TO BE MORE THAN THE MANUFACTURERS RECOMMENDATIONS. THE DEUTSCH RECOMMENDATION FOR D12000 SERIES TOOLS IS 5760 PSI MAXIMUM AND FOR THE DLT SERIES IS 10000 PSI MAXIMUM. IF PRESSURE IS GREATER THAN THE ABOVE VALUES INJURY AND DAMAGE CAN OCCUR.
 (7)  
Swage the union to the tube as shown in the manufacturer's recommended procedures.

 (8)  
Swage each end three times.


 S 358-379
 NOTE: After the initial swage, move the swage head between 30 and
____ 45 degrees from the previous swage position before you swage again.
 S 118-380
 (9)  
Clean the die blocks regularly.

 (10)
 Examine the end plates for loose retaining screws.


 S 218-381
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 20-11-05
 ALL  ú ú 02 Page 829 ú Jun 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 S 228-382
 (11)
 Examine the finished swage as shown in the manufacturer's recommended procedure or measure with Vernier caliper for dimensions as shown in Fig. 830.

 S 768-383

 (12)
 In the fuel tanks and vapor areas, do a check of the electrical resistance specifications across each tube/fitting interface (AMM 20-11-05/401).

 S 768-384

 (13)
 Make resistance measurements for all Permaswage repair installations in wing tanks and fuel vapor areas (AMM 20-11-05/401).

 S 798-385

 (14)
 For Permaswage fitting repairs in general areas, do a leak test as follows:

 (a)  
Pressurize the system for a minimum of 5 minutes.

 (b)  
Rub the tube and fittings with a clean white cloth to find leakage.

 


 S 218-386
 (15) Examine the tube-to-fitting interface for hydraulic leaks you can see.
 NOTE: When dimensional or leakage specifications are not met,
____ you can swage again. Then do a leak test. You must replace fittings you cannot seal.
 S 378-387
 (16) Apply BMS 10-11 primer to the Alodine areas of the finished tube joint where the bare metal is open.
 TASK 20-11-05-408-388
 11. Rynglok Union Installation (Fig./834)
__________________________
 A. General
 WARNING:_______DO NOT USE RYNGLOK FITTINGS ON ANY OXYGEN LINES. DAMAGE TO EQUIPMENT OR INJURY TO PERSONS CAN OCCUR.
 (1)  Rynglok tube to tube fittings are not to be used on fluid lines inside airplane fuel tanks. The rynglok tube to tube fitting is not qualified for these applications.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 20-11-05
 ALL  ú ú 02 Page 830 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 (2)  
The Rynglok in-line tube unions (Fig. 834), sizes 04, 06, 08, 10, 12, and 16 are used with 304 1/8 hard CRES to repair Ti-3AL-2.5 and 21-6-9 CRES. The same unions plus a size 20 are used with 6061-T6 aluminum tube to repair 6061-T6 aluminum tu be, provided the bare areas of the tubing are painted after swaging to limit the possibility of galvanic corrosion ocurring.

 (3)  
When you do a repair, remove the part of the tube with the damage. If the area of the tube damage is less than the value listed in (F ig. 805), use one Rynglok union for repair.

 (4)  
If the tube damage is longer than the value listed in (Fig. 805), put in a tube splice and install the splice with two fittings. The splice must be equal to or slightly shorter than the removed tube section. The minimum length of tubing to be removed is shown in (Fig. 836). Fittings and tubing material sizes are shown in (Fig. 835).


 B. Equipment
 (1) Swager - Hydraulic Fitting RTSK8-02-006 (Aeroquip Corporation, Jackson Plant, 300 S. East Ave., Jackson, MI 49203-1972)
 