• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-06 23:12来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 S 862-066
 CAUTION: MAKE SURE YOU KEEP CONTAMINATION OR UNWANTED MATERIAL AWAY FROM THE
_______ SENSITIVE DEVICE. CONTAMINATION OR UNWANTED MATERIAL NEAR THE SENSITIVE DEVICE CAN CAUSE A MALFUNCTION IN THE SENSITIVE DEVICE.
 (1)  Remove the system electrical power with the applicable
 Removal/Installation procedure.

 S 722-057
 WARNING: USE A WRIST STRAP WITH A MINIMUM GROUNDING LEAD RESISTANCE OF
_______ 250 KILOHMS AND A MAXIMUM OF 1.5 MEGOHMS. USE OF A LOW RESISTANCE WRIST STRAP CAN CAUSE INJURY TO PERSONS IF A HIGH VOLTAGE SOURCE IS TOUCHED.
 (2)  Do these steps to do a test of the wrist strap resistance:
 (a)  
Use an ohmmeter to make sure the wrist strap assembly has a minimum resistance of 250 kilohms and a maximum of 1.5 megohms.

 (b)  
Put the wrist strap on your wrist.

 (c)  
Use an ohmmeter to make sure the resistance is less than 10 megohm.


 S 422-062
 (3)  Connect the wrist strap into the ELECTROSTATIC GROUND JACK of the card file.
 S 862-016
 CAUTION: THE GROUNDING LEAD ON THE WRIST STRAP MUST TOUCH THE
_______ SKIN TO GIVE THE PROTECTION THAT IS NECESSARY. FAILURE TO USE THE WRIST STRAP CORRECTLY CAN CAUSE DAMAGE TO THE ESDS PRINTED CIRCUIT BOARDS.
 (4)  
Attach the wrist strap correctly on the person that will remove the printed circuit board.

 (5)  
Open the access door on the card file.

 S 862-018

 (6)  
From the location decal, find the printed circuit board to be installed.

 S 862-019

 (7)  
Remove the ESDS printed circuit board from the conductive bag or the carrier.


 S 862-017
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 20-41-02
 ALL  ú ú 01 Page 205 ú Oct 10/95
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 422-020
 (8)  
With the top and bottom (or left and right) extractors, put the printed circuit board into the card file.

 S 432-021

 (9)  
Attach the printed circuit card with the extractors.

 S 862-022

 (10)
 Close the access door for the card file.

 S 862-023

 (11)
 Remove the wrist strap.


 TASK 20-41-02-002-024
 4.  ESDS Metal Encased Units - Removal Handling___________________________________________
 A. General
 (1)  
The metal encased units can be put on a rack, the airplane structure, or a control panel.

 B.
Equipment

 (1)  
Wrist Strap - Conductive, (commercially available)

 (2)  
Ohmmeter


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 20-41-02
 ALL  ú ú 01 Page 206 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 (3)  Conductive electrical dust caps and connector
 covers

 NOTE: Conductive dust caps and connector
____ covers are black or grey in color.
 (a)
ITT Cannon - as applicable (stamped "CONDUCTIVE") ~............................................... | PART NUMBER | MARKING ON CAP | CONNECTOR | ................................................. | 025-1155-001 | BKAD1-A&B-R | BKAD1-A-R | | | | BKAD1-B-R | ................................................. | 025-1156-001 | BKAD1-C-R | BKAD1-C-R | ................................................. | 025-1157-001 | BKAD2&3-A&B-R | BKAD2-A-R | | | | BKAD2-B-R | | | | BKAD3-A-R | | | | BKAD3-B-R | ................................................. | 025-1158-001 | BKAD2&3-C-R | BKAD2-C-R | | | | BKAD3-C-R | 2...............….................….............1

 (b)
Souriau - as applicable ~................................................ | PART NUMBER | TYPE CONNECTOR | SHELL SIZE | .................................................. | 8660-1404 | Power | 1 | .................................................. | 8660-1405 | Signal | 1 | .................................................. | 8660-1406 | Power | 2 & 3 | .................................................. | 8660-1407 | Signal | 2 & 3 | 2..............…..................…..............1
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 STANDARD PRACTICES - AIRFRAME(139)