• 热门标签

当前位置: 主页 > 航空资料 > 飞行资料 >

时间:2010-09-27 07:35来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

PSP 604−1
1. SINGLE ENGINE PROCEDURES (CONT'D)
E. Single Engine Go-Around (Cont’d)
Go-around was due to engine failure during approach:
Yes
(7) In-Flight Engine
Failure/Shutdown................................. Accomplish Refer to POWER PLANT –
In-Flight Engine
Failure/Shutdown procedure in
this chapter.
− END −
No
(7) No further action required.
END
ABNORMAL PROCEDURES
Single Engine Procedures
05−03−6
REV 66, Feb 01/07
DOT Approved
CL−604 Airplane Flight Manual
PSP 604−1
1. AIR START
NOTE
During single engine operations, APU-assisted air start is not
always possible. Priority is given to a cross bleed start (i.e., highest
bleed air pressure source).
Use air turbine starter whenever possible. Refer to Chapter 2;
LIMITATIONS – POWER PLANT, for starter duty cycle.
A. Windmilling Air Start Procedure
NOTE
1. At thrust lever advance, N2 should be stable or increasing.
2. Windmill airstart efficiency is enhanced by attaining the
highest practical airspeed and N2 within the relight
envelope.
3. 300 knots is a target airspeed only, and may be exceeded to
obtain the minimum required N2 .
(1) Affected engine, thrust lever.................................Check affected lever SHUT OFF.
(2) FUEL, L (R) BOOST PUMP
switch/light ............................................................Check the following:
• PUMP ON lights on.
• L and R FUEL PUMP ON
advisory messages on.
(3) BLEED AIR, 10TH STAGE, L (R)
switch/light .......................................................Press out to close affected shut-off
valve.
Check 10TH CLOSED light
on.
(4) BLEED AIR, 10TH STAGE, ISOL
switch/light .......................................................Press out to close isolation valve.
Check 10TH ISOL OPEN light
out.
(5) BLEED AIR, APU LCV switch/light..................Press out to close load control valve.
Check APU LCV OPEN light
out.
(6) Start envelope ................................................. Establish
WINDMILLING AIR START ENVELOPE
ALTITUDE AIRSPEED ITT % N2
21,000 feet to
10,000 feet 300 KIAS up to
348 KIAS 90°C or less
12 to 55
10,000 feet to
8,000 feet 10 to 55
8,000 feet to SL 300 KIAS
ABNORMAL PROCEDURES
Air Start
05−04−1
REV 66, Feb 01/07

DOT Approved
CL−604 Airplane Flight Manual
PSP 604−1
1. AIR START (CONT'D)
A. Windmilling Air Start Procedure (Cont’d)
When ready to start:
(7) IGNITION, CONT switch/light............................Press in for continuous ignition.
Check the following:
• CONT ON, A and B lights
on.
• IGNITION A/B advisory
message on.
When ITT is 90°C or less and N2 is at least 12% (10% if below 10,000 feet):
(8) Affected engine, thrust lever.................................Select to IDLE when within start
envelope.
(9) Engine indications ..............................................Monitor carefully.
NOTE
1. If engine does not ignite in 25 seconds, retard thrust lever to SHUT
OFF, maintain at least 300 KIAS for 30 seconds and repeat
procedure. After ignition is achieved, monitor N2 acceleration rate.
N2 acceleration should be uninterrupted and positive at all times.
Stable idle must be achieved in 2 minutes of advancing thrust lever
to IDLE.
2. During windmilling airstart, attempt to keep the flight control inputs
to a minimum.
Engine start is successful:
Yes
When the engine is stabilized at Flight Idle:
(10) Thrust levers..................................................... Set as required.
(11) IGNITION, CONT switch/light..................Press out to turn off ignition.
Check the following:
• CONT ON, A and B lights
out.
• IGNITION A/B advisory
message out.
(12) BLEED AIR, 10TH STAGE,
L (R) switch/light .................................. As required
(13) BLEED AIR, APU LCV
switch/light ........................................... As required
(14) AIR-CONDITIONING, L (R)
PACK switch/light ......................................Press in to start affected pack.
Check L (R) PACK OFF light
out.
ABNORMAL PROCEDURES
Air Start
05−04−2
REV 66, Feb 01/07

DOT Approved
CL−604 Airplane Flight Manual
PSP 604−1
1. AIR START (CONT'D)
A. Windmilling Air Start Procedure (Cont’d)
(15) ANTI-ICE, COWL, L (R)
switches............................................... As required
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:庞巴迪挑战者604飞机飞行手册CL604 Airplane Flight Manual 1(131)