* 
Unlock the collars on the hold-open rods (a red stripe should be visible)
* 
Disconnect and stow the hold-open rods
* 
Operate the DOWN button until the T/R half closes.
* 
Close the T/R latches.
Training Information Point 
A T/R half opens in approximately 40 seconds. When you open the two T/R halves at the same time, it takes approximately 100 seconds. A T/R half closes in approximately 25 seconds. You can close the two T/R halves at the same time. 
If the aft hold-open rod does not lock when you open the T/R, push the UP button to move the T/R a very short distance. The aft hold-open rod collar will lock and you will see the yellow stripe. 
When you open the right T/R half you must open the left and right fan cowls. This is because the v-band latch handle will hit left fan cowl panel if the cowl is not open. 
EFFECTIVITY BEJ ALL  71-12-00  
Page 18  
D633W101-BEJ  May 05/2004 
PW4000 SERIES ENGINES
777 AIRCRAFT MAINTENANCE MANUAL
PDOS -OPERATION -THRUST REVERSER
EFFECTIVITY BEJ ALL  71-12-00  
Page 19  
D633W101-BEJ  Sep 05/2002 
PDOS -MANUAL OPERATION
When there is no airplane power you use the manual drive lug and the solenoid valves on the PDOS pump/power pack to open and close the fan cowls and the thrust reverser (T/R) halves. A decal on the pump/power pack shows the manual operation procedures. 
The manual drive lug uses a 3/8 inch square drive. 
Open the Fan Cowl and Thrust Reverser 
This is a summary of the procedure to open a fan cowl or T/R half: 
* 
Use a flat-blade screwdriver to set the solenoid valves to the positions to open the related cowl
* 
Turn the manual drive lug
* 
When the cowl is open and the hold-open rods lock, set the solenoid valves to the positions to close the related cowl
* 
Push and hold the V5 solenoid valve to put the weight of the cowl on the hold-open rods
* 
Put the solenoid valves back to their initial positions.
Close the Fan Cowl and Thrust Reverser 
This is a summary of the procedure to close a fan cowl or T/R half: 
* Use a flat-blade screwdriver to set the solenoid valves to the positions to open the related cowl 
* 
Turn the manual drive lug to move the cowl up and then unlock the hold-open rods
* 
Set the solenoid valves to the positions to close the related cowl
* 
Push and hold the V5 solenoid valve to close the cowl
* 
Put the solenoid valves back to their initial positions.
Training Information Point 
The pump/power pack is approximately 14 ft. (4.3m) from the ground. There is a safety harness attach point with a receptacle for a safety harness. The safety harness attach point is aft of the number one strut fairing adjacent to the pump/power pack. Attach the safety harness to the attach point when you operate the pump/power pack. 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:777 AMM 飞机维护手册 动力装置 Power Plant PW 777 AIRCRAFT MAINTENANCE MANUAL(25)