DFCS BITE PAGES - RIGGING - STABILIZER 1
General
This shows an example of one of the rigging tests, the stabilizer rigging. You can follow the test through each of the stabilizer rigging pages. You can always go back to the RIGGING INDEX page if you push LSK 6R when it says PREV MENU.
January 1, 2004
22-11
- 46 -
SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved
SOUTHWEST AIRLINES.
737-700 MAINTENANCE TRAINING MANUAL

A22-11-00-135.fm
DFCS BITE PAGES - RIGGING - STABILIZER 1

January 1, 2004
22-11
SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved
SOUTHWEST AIRLINES.
737-700 MAINTENANCE TRAINING MANUAL
DFCS BITE PAGES - RIGGING - STABILIZER 2 Stabilizer Rigging Continue This shows more pages of the stabilizer rigging test.
January 1, 2004
22-11
- 48 -
SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved
SOUTHWEST AIRLINES.
737-700 MAINTENANCE TRAINING MANUAL
PREVIOUS
GRAPHIC


A22-11-00-136.fm
DFCS BITE PAGES - RIGGING - STABILIZER 2

January 1, 2004
22-11
SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved
SOUTHWEST AIRLINES.
737-700 MAINTENANCE TRAINING MANUAL
DFCS -STABILIZER B DIMENSION
General
When you need to accurately measure the B dimension of the stabilizer, use the trammel bar or a steel measurement tape. Measure the distance between the center of the upper gimbal pin and the center of the lower gimbal pin.
January 1, 2004
22-11
- 50 -
SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved
SOUTHWEST AIRLINES.
737-700 MAINTENANCE TRAINING MANUAL
A22-11-00-109.fm
B DIMENSION 1 TRAMMEL BAR
THE B DIMENSION IS MEASURED BETWEEN THE
CENTER OF THE UPPER AND LOWER GIMBAL PINS

DFCS -STABILIZER B DIMENSION
January 1, 2004
22-11
- 51 -
SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved
SOUTHWEST AIRLINES.
737-700 MAINTENANCE TRAINING MANUAL
DFCS BITE PAGES - MCP TESTS
General
The MCP tests lets you do several tests of the mode control panel. In the tests you do a check of the function of the switches and the displays. You also do a test of all of the mode selector switches.
To do these tests, push LSK 3L on the EXTENDED MAINTENANCE page. The next page is the SELECT CHANNEL FOR TEST page. After you select the channel, you will see the MCP TEST AUTOTEST INITIALIZATION page.
MCP TEST AUTOTEST INITIALIZATION Page
Like all the other initialization pages, this page gives instructions to setup the autotests. The test sequence is the same as when you select CURRENT STATUS and AUTOPILOT tests. The pages look very similar except the title has MCP COMPLETE TEST in it instead of CURRENT STATUS and AUTOPILOT.
January 1, 2004
22-11
- 52 -