minutes indicating the CMU is restarting.
To verify the correct ACARS CMU software load, use the MCDU and access the ACARS. From the ACARS Main Menu select DIAGNOSTICS. From the DIAGNOSTICS menu select PART NO. The part numbers page will display the CMU software. You can also access the Parts Number page from the Maintenance Menu.
NOTE:  If you access the Part Numbers page from the DIAGNOSTICS menu, you will see a RETURN selectable in Line 5L, and MAIN MENU selectable in Line 6L. Using LSK 5L will take you back to the DIAGNOSTIC page, and using LSK 6L will take you back to the MAIN MENU.
NOTE:  If you access the Part Numbers page from the MAINTENANCE menu, you will see MAINTENANCE selectable in Line 6L. Using LSK 6L will take you back to the MAINTENANCE MENU.
December 1, 2004
23-27

- 40 -
SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved
SOUTHWEST AIRLINES.
SWACOM TRAINING GUIDE

LED STATUS
INDICATORS

 


23-27-AC-010
ACARS - TRAINING INFORMATION POINT - SOFTWARE LOADING
December 1, 2004
23-27

- 41 -
SOUTHWEST AIRLINES PROPRIETARY(c) All rights reserved
SOUTHWEST AIRLINES.
SWACOM TRAINING GUIDE

ACARS - TRAINING INFORMATION POINT - SOFTWARE LOADING

23-27-AC-010
ACARS Software
The ACARS CMU is software loadable.
-Software can be loaded using the PCMCIA card slot on the front of the CMU and a PCMCIA card. -A second method is to use a PDL at the front of the CMU using the data load connector. -On the 737-700 ONLY the software can be loaded using a PDL and the data loading panel P61 located in the flight deck.

The ACARS CMU is loaded with three types of software:
-Southwest Operational Software - basic operation information -HGI - Honeywell Generated Interface Software -AMI - Airline modifiable software

NOTE:  THE SOFTWARE MUST BE LOADED IN THE ORDER LISTED ABOVE.
Training Point
The most common method of loading software into the CMU is using the PCMCIA card slot on the front of the CMU and a PCMIA card. To load the software, do these tasks:
-Pull the CMU circuit breaker.
-Open the PCMIA slot cover,
-Insert the PCMIA card containing the Operational Software.
-Close the Circuit breaker

-The green and red LEDs on the front of the box will flash for about 3 minutes, followed by a solid green and red for approximately 30 minutes. The solid green and red LED indicates software is being loaded.
-Remove the PCMCIA card when the red LED extinguishes.
-Insert the PCMCIA containing the HGI database software.
-The PCMCIA card must be inserted within 20 seconds of

removing the previous PCMCIA card. -The green and red LED will illuminate for about 5 minutes. -Remove card when the red LED extinguishes. -Insert the PCMCIA card containing the AMI Database Software. It
must be inserted within 20 seconds. -The green and red LED will illuminate for about 5 minutes. -Remove the PCMCIA when the red LED extinguishes. -Close the PCMCIA slot cover and tighten thumbscrew. -The green and red LED on the front of the CMU will flash for three
 