EFFECTIVITY BEJ ALL 23-33-00
Page 23
D633W101-BEJ Jan 05/2002
PSS -OEU INSTALLATION -LAVATORIES AND LOWERED CEILING AREAS
General
There are overhead electronics units (OEUs) in these locations:
*
Each lavatory
*
Above each passenger door
*
Some lowered ceiling panels.
The diagram shows a typical lavatory and typical door area with lowered ceiling panels.
Lavatories
The lavatory OEUs mount to a passenger service unit (PSU) rail adjacent to the lavatory.
Training Information Point
You must remove ceiling panels adjacent to the lavatory to get to the OEU.
Overdoor Panels
Panels over each passenger door have an OEU.
Release the latches of the overdoor panel and lower it to get access to the OEU.
Lowered Ceiling Panels
The flight deck aisle access panel (near door 1 left) and a lowered ceiling panel at door 4 left have OEUs.
Training Information Point
Lower the flight deck aisle access panel to get access to the OEUs in the door 1 area.
Release the latches of the door 4L overdoor panel and lower it to get access to the OEU on the lowered ceiling panel.
EFFECTIVITY BEJ ALL 23-33-00
Page 24
D633W101-BEJ Sep 05/2002
PSS -OEU INSTALLATION -LAVATORIES AND LOWERED CEILING AREAS
EFFECTIVITY BEJ ALL 23-33-00
Page 25
D633W101-BEJ Jan 05/2002
PSS -PASSENGER SERVICE UNIT
General
The passenger service unit (PSU) has these passenger service system items:
*
Row call lights
*
Reading lights
*
Passenger information signs.
EFFECTIVITY BEJ ALL 23-33-00
Page 26
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
PSS -PASSENGER SERVICE UNIT
EFFECTIVITY BEJ ALL 23-33-00
Page 27
D633W101-BEJ Jan 05/2002
PSS -PASSENGER INFORMATION SIGNS
General
The passenger information signs show passengers these PSS conditions:
*
No smoking
*
Lavatory occupied
*
Fasten seat belt.
EFFECTIVITY BEJ ALL 23-33-00
Page 28
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
PSS -PASSENGER INFORMATION SIGNS
EFFECTIVITY BEJ ALL 23-33-00
Page 29
D633W101-BEJ Jan 05/2002
PSS -TYPICAL LAVATORY COMPONENTS
General Lavatory Door Latch
These lavatory components send and get signals through an The lavatory door latch sends a signal to the PSS to make the overhead electronics unit (OEU): lock door sign go off and a lavatory occupied sign come on.
*
Lavatory call light/reset switch
*
Return to seat sign
*
Lavatory call switch
*
Lock door sign
*
Lavatory door latch.
Lavatory Call Light/Reset Switch
The lavatory call light comes on when you push the lavatory call switch. Attendants push this light/switch to cancel lavatory calls.
Return to Seat Sign
The return to seat sign comes on when the fasten seat belt signal is active and and cabin pressure is normal.
Lavatory Call Switch
Passengers use the lavatory call switch to call an attendant. The lavatory call switch makes the PSS do these things:
*
The lavatory call light outside the lavatory comes on
*
A lavatory master call light at an attendant station comes on
*
A signal goes to the passenger address system for a chime.
Lock Door Sign
The lock door sign is on when the lavatory door is not locked.
EFFECTIVITY BEJ ALL 23-33-00
Page 30
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
PSS -TYPICAL LAVATORY COMPONENTS
EFFECTIVITY BEJ ALL 23-33-00
Page 31
D633W101-BEJ Jan 05/2002
PSS -CONFIGURATION DATABASE PROGRAMMED ITEMS
General
The cabin management system (CMS) configuration database supplies details of CMS operation. For the PSS, the database gives configuration data for these items:
*
Master call light assignments
*
Row call light assignments
*
Lavatory call light assignments
*
Reading light assignments
*
Chime mute areas
*
Passenger information sign control
*
Panels for PSS on/off control
*
OEU configuration.
Master Call Light Assignments
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:777 AMM 飞机维护手册 通讯 Communications 1(58)