The P210 right power management panel has the PAX MASTER CALL LT circuit breaker.
The P110 left power management panel has these components:
*
ZONE MGMT UNIT 1 circuit breaker
*
OEU ZONE1 XFER BUS circuit breaker
*
OEU ZONE1 MAIN BUS circuit breaker.
P210 Right Power Management Panel
The PAX MASTER CALL LT circuit breaker connects 28v dc to the ZMU.
P110 Left Power Management Panel
The ZONE MGMT UNIT 1 circuit breaker connects 115v ac to the ZMU.
The OEU ZONE1 XFER BUS and OEU ZONE1 MAIN BUS circuit breakers each connect 115v ac power to all three columns of OEUs.
EFFECTIVITY BEJ ALL 23-33-00
Page 10
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
PSS -POWER INTERFACE -ZONE 1
EFFECTIVITY BEJ ALL 23-33-00
Page 11
D633W101-BEJ Jan 05/2002
PSS -POWER INTERFACE -ZONE 2
General The OEU ZONE2 XFER BUS circuit breaker connects 115v ac
power to all of the OEUs in zone 2. Circuit breakers on the right power management panel control power to these zone 2 components:
*
Zone management unit (ZMU) 2
*
Overhead electronics units (OEUs).
The P210 right power management panel has these components:
*
PAX MASTER CALL LT circuit breaker
*
ZONE MGMT UNIT 2 circuit breaker
*
OEU ZONE2 LEFT MAIN BUS circuit breaker
*
OEU ZONE2 CENTER MAIN BUS circuit breaker
*
OEU ZONE2 RIGHT MAIN BUS circuit breaker
*
OEU ZONE2 XFER BUS circuit breaker.
P210 Right Power Management Panel
The PAX MASTER CALL LT circuit breaker connects 28v dc to ZMU 2. The ZONE MGMT UNIT 2 circuit breaker connects 115v ac to the ZMU.
These circuit breakers each connect 115v ac power to a column of OEUs:
*
OEU ZONE2 LEFT MAIN BUS to the left OEUs
*
OEU ZONE2 CENTER MAIN BUS to the center OEUs
*
OEU ZONE2 RIGHT MAIN BUS to the right OEUs.
EFFECTIVITY BEJ ALL 23-33-00
Page 12
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
PSS -POWER INTERFACE -ZONE 2
EFFECTIVITY BEJ ALL 23-33-00
Page 13
D633W101-BEJ Jan 05/2002
PSS -POWER INTERFACE -ZONE 3
General
Circuit breakers on the left and right power management panels control power to these zone 3 components:
*
Zone management unit (ZMU) 3
*
Overhead electronics units (OEUs).
The P110 left power management panel has these components:
*
ZONE MGMT UNIT 3 circuit breaker
*
OEU ZONE3 LEFT MAIN BUS circuit breaker
*
OEU ZONE3 CENTER MAIN BUS circuit breaker
*
OEU ZONE3 RIGHT MAIN BUS circuit breaker
*
OEU ZONE 3 XFER BUS circuit breaker
The PAX MASTER CALL LT circuit breaker is on the P210 right power management panel.
P110 Left Power Management Panel
The ZONE MGMT UNIT 3 circuit breaker connects 115v ac to the ZMU.
These circuit breakers each connect 115v ac power to a column of OEUs:
*
OEU ZONE 3 LEFT MAIN BUS to the left OEUs
*
OEU ZONE 3 CENTER MAIN BUS to the center OEUs
*
OEU ZONE 3 RIGHT MAIN BUS to the right OEUs.
The OEU ZONE 3 XFER BUS circuit breaker connects 115v ac power to all of the OEUs in zone 3.
P210 Right Power Management Panel
The PAX MASTER CALL LT circuit breaker connects 28v dc to the ZMU.
EFFECTIVITY BEJ ALL 23-33-00
Page 14
D633W101-BEJ Sep 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
PSS -POWER INTERFACE -ZONE 3
EFFECTIVITY BEJ ALL 23-33-00
Page 15
D633W101-BEJ Jan 05/2002
777 AIRCRAFT MAINTENANCE MANUAL
THIS PAGE IS INTENTIONALLY LEFT BLANK
23-33-00
Page 16 D633W101-BEJ Jan 05/2002
PSS -INTERFACES
General
The passenger service system (PSS) uses an ARINC 629 interface and an in-flight entertainment (IFE) system ARINC 628 head-end interface to get data from other systems. An intersystem (I/S) bus connects the three cabin zones. Other buses connect the other PSS components.
The passenger interface for PSS is through an IFE system ARINC 628 zone interface.
The diagram shows zone 1 interfaces. The other zones are the same.
ARINC 629
The passenger address/cabin interphone (PA/CI) controller connects to the left systems ARINC 629 bus. The cabin system management unit (CSMU) connects to the right systems ARINC 629 bus. The PA/CI and CSMU get data from these systems to control the passenger information signs:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:777 AMM 飞机维护手册 通讯 Communications 1(56)