27-31-00
ALL ú ú 10 Page 582N ú May 28/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
S 485-284
(2)
Remove the pogo tools from the PCU pogos.
S 215-206
(3)
Make sure that these circuit breakers on the P11 panel are closed:
(a)
11B19 or 11A19, STAB TRIM ALT (IF INSTALLED)
(b)
11C12, STAB TRIM SHUTOFF LEFT
(c)
11C13, STAB TRIM SHUTOFF RIGHT
(d)
11H11 or 11C05, STAB TRIM CONT L
(e)
11H20, STAB TRIM CONT R
S 215-207
(4)
Make sure that the L, R, and C FLT CONTROL SHUTOFF switches on the P61 panel are at the ON position.
S 215-208
(5)
Make sure that the RIGHT and CENTER STAB TRIM SHUTOFF valve switches on the P10 panel are in the NORM position.
S 415-209
(6)
Close the left and right access panels for the elevator PCAs, 335DB and 345DB (AMM 06-42-00/201).
F.
Prepare for the Test (Procedure 2 - Tee and Pressure Gage Method)
S 865-299
(1) Make sure pressure is removed from the left, right and center hydraulic systems (AMM 29-11-00/201).
S 015-435
WARNING: STAY OFF THE SERVICE ACCESS DOOR, 311AL, AND THE ACCESS DOOR
_______ FOR THE CONTROLS BAY, 313AL. YOUR WEIGHT CAN CAUSE THE SPRING-LOADED LATCHES TO RELEASE. IF YOU FALL THROUGH THE DOOR, INJURY CAN OCCUR.
(2)
Open the access door for the forward stabilizer compartment, 311AL (AMM 06-42-00/201).
G.
Elevator Pressure Bypass Valve Test (Procedure 2)
S 495-307
(1) Do the steps that follow to install the tee fitting and the pressure gage in the hydraulic line.
NOTE: When you disconnect the hydraulic lines, use a bucket to
____
catch the hydraulic fluid that spills.
(a)
Find the titanium pressure line at the pressure reducer bypass valve.
(b)
Find the location where the titanium pressure line joins the flexible line.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
27-31-00
ALL ú ú 11 Page 582O ú Jan 28/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 飞行操纵 FLIGHT CONTROLS 3(60)