LEVER
FWD
FLOW CONTROL UNIT
C
Supernumerary Oxygen System Components
Figure 102 (Sheet 4)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
35-21-00
ALL ú CONFIG 3 ú 02 Page 105 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
M14764
A
747-400
FAULT ISOLATION/MAINT MANUAL
OXYGEN CYLINDERS SEE
SHUTOFF PRESSURE
OVERBOARD
INBD
SUPERNUMERARY OXYGEN CYLINDER (EXAMPLE)
Supernumerary Oxygen Cylinder
Figure 102 (Sheet 5)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
35-21-00
ALL ú CONFIG 3 ú 02 Page 106 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
M14778
A
747-400 FAULT ISOLATION/MAINT MANUAL
RESERVOIR BAG
MASKS WITH WARNING STREAMERS
Supernumerary Oxygen Mask Figure 102 (Sheet 6)
M14789
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
35-21-00
ALL ú CONFIG 3 ú 02 Page 107 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 FAULT ISOLATION/MAINT MANUAL
Voltage Averaging Unit
Figure 102 (Sheet 7)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
35-21-00
ALL ú CONFIG 3 ú 02 Page 108 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
M14832
A
747-400 MAINTENANCE MANUAL
PASSENGER OXYGEN SYSTEM - MAINTENANCE PRACTICES
_______________________________________________
TASK 35-21-00-802-050-001
1. Passenger Oxygen System_______________________
A. General
(1) This configuration NOT USED.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. CONFIGURATION NOT USED ú
35-21-00
ú CONFIG ú 01N Page 201 ú Oct 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
SUPERNUMERARY OXYGEN SYSTEM - MAINTENANCE PRACTICES
___________________________________________________
1. General_______
A. This procedure describes the folowing tasks:
(1)
Changing the oxygen cylinder wiring to reflect the number of oxygen cylinders installed on the airplane.
(2)
Resetting the Supernumerary Oxygen System after system operation.
B. This Chapter/Section/Subject/Page Block uses Configurations (CONFIGs) to identify different oxygen system configurations used by operators: CONFIG 1: Passenger Oxygen System CONFIG 2: Supernumerary Oxygen System If an operator does not have a particular configuration in their fleet, that CONFIG's procedure will be LIMITED as CONFIGURATION NOT USED and will contain no instructions.
(1) Put the airplane back in its usual condition after mask operation.
C. A minor wiring change to the connector on the voltage averaging unit is needed when the number of active supernumerary oxygen cylinders is changed. The wiring change is needed to register the correct system pressure on the EICAS status page.
D. The voltage averaging unit is located in the ceiling beam in the right side of the forward cargo compartment. It is also aft of the cargo door at approximately Sta 740. Access is through the access panels to the oxygen cylinders.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 氧气 OXYGEN(48)