 (a)  Slowly turn the shutoff valve until it is fully open. NOTE: The shutoff valve can be closed by hand which is
____ equivalent to 25 pound-inches.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 35-11-18
 ALL  ú ú 06 Page 405 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 (b)  
Close the shutoff valve one-fourth of a turn.

 (c)  
Install a lockwire on the shutoff valve.


 NOTE: Use the 0.020 inch diameter copper lockwire
____
 (AMM 20-11-28/401).

 S 864-015
 (8) Remove the DO-NOT-CLOSE tags and close these circuit breakers:
 (a)  P7 Overhead Circuit Breaker Panel
 1) 7A20 CAPT INTERPHONE
 2) 7A21 OBS INTERPHONE
 3) 7A22 F/O INTERPHONE

 S 714-016
 (9) Do the tasks: "Crew Oxygen Operational Test" (AMM 35-11-00/501).
 TASK 35-11-18-004-017
 4. Mask/Regulator Removal
______________________
 A. References
 (1)  
AMM 35-00-00/201, Oxygen

 (2)  
IPC 35-11-18

 (3)  
WDM 23-51-11, 23-51-12, 23-51-13, 23-51-14


 B. Access
 (1)  Location Zone
 221 Control Cabin Left
 222 Control Cabin Right

 C. Procedure
 S 914-073
 (1)  
Read and obey the safety precautions and general instructions before you do the maintenance (AMM 35-00-00/201).

 S 864-018

 (2)  
Open these circuit breakers and attach DO-NOT-CLOSE tags:


 (a)  P7 Overhead Circuit Breaker Panel
 1) 7A20 CAPT INTERPHONE

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 35-11-18
 ALL  ú ú 07 Page 406 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 2) 7A21 OBS INTERPHONE 3) 7A22 F/O INTERPHONE S 864-045 CAUTION: DO NOT TORQUE THE SHUTOFF VALVE ON A CREW OXYGEN CYLINDER MORE
_______ THAN 25 POUND-INCHES. THIS CAN CAUSE DAMAGE TO THE SHUTOFF VALVE.
 (3)  Close the shutoff valve on each applicable cylinder slowly. NOTE: Some airplanes have an optional second oxygen cylinder.
____
 NOTE: The shutoff valve can be tightened by hand which is

____
 equivalent to 25 pound-inches.

 S 714-078
 (4)  
Set the dilution control lever on the regulator to 100 %. S 034-057

 (5)  
Set the PRESS TO TEST knob to EMERGENCY. S 034-059

 (6)  
Move the PRESS TO TEST AND RETEST lever on the mask stowage box to bleed the oxygen lines.

 S 034-021

 (7)  
Disconnect the microphone connector from the stowage box. S 024-022

 (8)  
Remove the mask/regulator from the stowage box. S 034-023

 (9)  
Install clean caps or plugs to the open fittings and ports. NOTE: Clean metal caps must be used where the cap engages the


____ connector threads. New plastic caps must be used if the cap does not engage the connector threads.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 35-11-18
 ALL  ú ú 03 Page 407 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 TASK 35-11-18-404-024
 5.  Mask/Regulator Installation___________________________
 A. References
 (1)  
AMM 35-00-00/201, Oxygen

 (2)  
35-11-00/501, Crew Oxygen System

 (3)  
35-11-18/201, Mask, Demand Regulator and Stowage Box

 (4)  
IPC 35-11-18

 (5)  
WDM 23-51-11, 23-51-12, 23-51-13, 23-51-14


 B. Access
 (1)  Location Zone
 221 Control Cabin Left
 222 Control Cabin Right
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 氧气 OXYGEN(40)