TASK 28-42-00-810-850
FQIS - FQIC Pin Programming Parity Error
WARNING : OBEY THE FUEL SAFETY PROCEDURES.
_______
WARNING : WHEN YOU DO WORK ON THE FUEL SYSTEM WIRING, YOU MUST USE TEST
_______ EQUIPMENT THAT IS APPROVED (REFER TO INTERNATIONAL OR NATIONAL SPECIFICATIONS FOR INTRINSICALLY SAFE TEST EQUIPMENT, E.G. EN50-020, UL913 OR EQUIVALENT). TEST EQUIPMENT THAT IS NOT APPROVED CAN CAUSE FIRE OR AN EXPLOSION.
1. Possible Causes
_______________
- FQIC (3QT)
- aircraft wiring between the FQIC (3QT) rack connector and terminal block (202VT) 92VU122
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 28-42-34-000-001 Removal of the Fuel Quantity-Indicating Computer (FQIC) (3QT) AMM 28-42-34-400-001 Installation of the Fuel Quantity-Indicating Computer (FQIC) (3QT) ASM 28-42/01
3. Fault Confirmation
__________________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FUEL/FQI/CHAN/1 1QT A13 121VU FUEL/FQI/CHAN/2 2QT M27
B. To keep the number of computer removals to a minimum do the Power On BITE test of the FQI system as follows:
(1) Apply electrical power to the FQI system. OR (if the FQIS is already powered). Reset the FQIC. (Open, then after 10 seconds, close the two CBs 1QT
and 2QT).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 301-399, ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page C275
May 01/05 CES
(2) When the BITE test is complete (XX shown on the FQI for 35 seconds and the display has no dashes for 60 seconds) set the MCDU to:
(a) CFDS
(b) SYSTEM REPORT/TEST
(c) FUEL
(d) FQIS STATUS.
(3) Examine the FQIS STATUS page to see if it agrees with the initial defect.
(4) If the PIN PRG PARITY ERROR 3QT message is not shown:
- maintenance steps are not necessary.
4. Fault Isolation
_______________
A. If the PIN PRG PARITY ERROR 3QT message is shown in Para. 3.B.(3): - on the MCDU set to INPUT PARAMETERS, Page 3.
(1) Do a check of the bit location H1:
- make sure that it shows a 1.
(2) Do a check of the bit locations G1 and K1:
- make sure they both show a 0.
(3) If the bits identified in Para 4.A. (1) and (2) above are not correct:
- do a check of the aircraft wiring between the FQIC (3QT) rack connector and terminal block (202VT) 92VU122 as shown in the table below, and (Ref. ASM 28-42/01).
Table of the FQIC pin programming connections with the FQIs shown in kilogrammes (kg)
-----------------------------------------------------------------------------| Bit | Signal | FQIC Pin | Terminal Block 202VT | | position | discription | allocation |---------------------------------------| | | | | Terminal allocation | Signal level | |----------|-------------|------------|---------------------|-----------------| | H1 | A320/321 | C05E | 16J | Ground/earth | | G1 | KG/LBS | C06E | 13A | Not connected | | K1 | Program pin | C05G | 13V | Not connected | | | parity | | | | -----------------------------------------------------------------------------
(4) Repair all the unserviceable wiring and connectors.
(5) Do the procedure given in Para 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 301-399, ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page C276
May 01/05 CES
(6) If the fault continues replace the FQIC (3QT), (Ref. AMM TASK 28-42-34-000-001) and (Ref. AMM TASK 28-42-34-400-001).
NOTE : Make sure that the FQIC to be installed is of the same type as
____
that removed. (Simmons Precision - Sextant Avionique).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 301-399, ∞∞28-42-00∞∞∞∞∞∞∞∞∞∞Page C277
May 01/05 CES
TASK 28-42-00-810-854
Fuel Quantity Probes, Left Wing Tank Double Probe Failure WARNING : OBEY THE FUEL SAFETY PROCEDURES.