EFF : ALL ∞∞I-LOCAL ∞∞∞∞∞∞∞∞∞∞Page 7
CES
R
R
QCCU (960WR)
____________ OXYGEN-QCCU indication light comes on ............................. 35-LOCAL REFUEL/DEFUEL Pnl(800VU)
________________________
DEFUEL/XFR/OPEN lamp Not on during LTS (filament/lights) TEST ..... 28-LOCAL DEFUEL/XFR/OPEN lamp Not on during LTS (filament/lights) TEST ..... 28-OBSV REFUEL/DEFUEL PNL(800VU)
________________________
FUEL - REFUEL/DEFUEL - DEFUEL/XFR/OPEN lamp not on ................ 28-LOCAL FUEL - REFUEL/DEFUEL - DEFUEL/XFR/OPEN lamp not on ................ 28-OBSV FUEL - REFUEL/DEFUEL - END legend at (5QT) preselector flashes .... 28-LOCAL FUEL - REFUEL/DEFUEL - END legend at (5QT) preselector flashes .... 28-OBSV
ZONE: 211
_________ UNIT FAIL is displayed on the MDDU display ........................ 31-LOCAL ACP (11VU/20 VU)
________________ MECH indicator light does not come on ............................. 23-LOCAL ADIRS CDU (20VU)
________________
IR - DELAYED MAINT comes into view on the ADIRS CDU display ....... 34-ECAM
IR - DELAYED MAINT comes into view on the ADIRS CDU display ....... 34-LOCAL
ON BAT legend stays off at ADIRS power up test .................... 34-LOCAL
STS - CDU FAULT comes into view on the ADIRS CDU display .......... 34-LOCAL
STS - GNSSU 1 FLT comes into view on the ADIRS CDU display ........ 34-LOCAL
STS - GNSSU 2 FLT comes into view on the ADIRS CDU display ........ 34-LOCAL
AVIONICS COMPT (Z125)
_____________________ CSM/G GCU red led on .............................................. 24-LOCAL ELEC Pnl (35VU)
_______________
DC GEN - BAT1 voltage below 25.5V ................................. 24-LOCAL DC GEN - BAT2 voltage below 25.5V ................................. 24-LOCAL ELEC pnl (35VU)
_______________
ELEC - EXT PWR p/bsw -AVAIL legend stays on when p/bsw pushed ..... 24-LOCAL ELEC - EXT PWR p/bsw -AVAIL legend stays on when p/bsw pushed ..... 24-OBSV ELEC - GEN1 p/bsw-FAULT legend on ................................. 24-LOCAL
R
EFF : ALL ∞∞I-LOCAL ∞∞∞∞∞∞∞∞∞∞Page 8
CES
ELEC - GEN1 p/bsw-FAULT legend stays off .......................... 24-LOCAL
ELEC - GEN1 p/bsw-FAULT legend stays off .......................... 24-OBSV
R ELEC - GEN2 p/bsw-FAULT legend on ................................. 24-LOCAL
ELEC - GEN2 p/bsw-FAULT legend stays off .......................... 24-LOCAL
ELEC - GEN2 p/bsw-FAULT legend stays off .......................... 24-OBSV
EXT PWR Pnl (108VU)
___________________
COCKPIT CALL indicator light does not come on ..................... 23-LOCAL
ELEC - EXT PWR NOT IN USE indicator light stays on ................ 24-LOCAL
ELEC - EXT PWR NOT IN USE indicator light stays on ................ 24-OBSV
EXT PWR AVAIL indicator light stays off ........................... 24-LOCAL
EXT PWR NOT IN USE indicator light stays off ...................... 24-LOCAL
FLT ATTND PLN (Z221)
____________________
WTR/WASTE - TOILET SHUT OFF WATER SUPPLY .......................... 38-LOCAL
WTR/WASTE - TOILET VACUUM SYSTEM DISABLE - WASTE TANK Full ........ 38-LOCAL
FLT ATTND PNL (Z221)
____________________
WTR/WASTE - TOILET NO WASTE QUANTITY DATA AVAILABLE ............... 38-LOCAL
FUEL PNL (40VU)
_______________
FUEL - CROSSFEED - P/BSW-4QE ON legend on ......................... 28-ECAM
FUEL - CROSSFEED - P/BSW-4QE ON legend on ......................... 28-LOCAL
FUEL - CROSSFEED - P/BSW-4QE OPEN legend on ....................... 28-ECAM
FUEL - CROSSFEED - P/BSW-4QE OPEN legend on ....................... 28-LOCAL
FUSELAGE (Z 125)
________________
OVERBOARD discharge indicator yellow .............................. 35-LOCAL OXY CREW - rapid loss of oxygen with yellow OURB discharge IND is yellow ............................................................ 35-LOCAL
L/G CTL IND Pnl (402VU)