-------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
R  B. Nicks, scratches,  Maximum depth must be  
R  chafing in  less than 10 percent of  
R  straight section  the wall thickness of  
R  the duct. There is no  
R  limit to the number of  
R  nicks, scratches or  
R  chafing permitted in the  
straight section of the  
duct.  
R  C. Nicks, scratches,  Maximum depth must be  
R  chafing in bends.  less than 10 percent of  
R  the wall thickness of  
R  the duct.  
R  
R  
R  
R 
2. Examine the bushings in the brackets, look for:  
R  A. Wear  0.26 in. (6.6 mm)  
R  maximum inside diameter  
R  of the bushing.  
R  
R  
5. Close-up________ 
 Subtask 80-13-43-410-052 
 A. Close Access
If the damage is less than the allowable limits, repair the damage at next A check. If the damage is more than the allowable limits, replace the duct (Ref. TASK 80-13-43-000-041) and (Ref. TASK 80-13-43-400-041). 
If the damage is less than the allowable limits, repair the damage (Ref. CMM 71-00-17). If the damage is more than the allowable limits, replace the duct (Ref. TASK 80-13-43-000-041) and (Ref. TASK 80-13-43-400-041).
If the wear is more than the acceptable limits, replace the duct (Ref. TASK 80-13-43-000-041) and (Ref. TASK 80-13-43-400-041).
 (1) Close the fan cowl doors (Ref. TASK 71-13-00-410-040): FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR
(2) Remove the access platform(s).
 F 『 EEFF : ALL E Page 60380-13-43
 E E Aug 01/02 E E ECES E F 『 E C F M E E E E 56-5B E E E
 (3) Remove the warning notice(s).
 F 『 EEFF : ALL E Page 60480-13-43
 E E Aug 01/02 E E ECES E