(2) Remove the access platform(s).
(3) Remove the warning notice(s).
F 『 EEFF : ALL E Page 60380-13-42
E E Aug 01/02 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
DUCT - FLEXIBLE STARTER - REMOVAL/INSTALLATION
______________________________________________
TASK 80-13-43-000-041
Removal of the Upper Starter Duct
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific blanking plugs
No specific warning notice
No specific access platform 1 m (3 ft. 3 in.)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors
80-13-43-991-300 Fig. 401
3. Job Set-up
__________ R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
Subtask 80-13-43-941-050
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a warning notice to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
F 『 EEFF : ALL E Page 40180-13-43
E E Aug 01/05 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a warning notice to tell persons not to energize the FADEC 1(2).
(4) On the AIR COND panel 30VU:
- make sure that the APU BLEED pushbutton switch is released (ON legend is off),
- put a warning notice to tell persons not to operate the pneumatic system.
(5) On the HP ground connector:
- put a warning notice to tell persons not to pressurize the pneumatic system.
R **ON A/C 301-399,
R Subtask 80-13-43-941-050-A
R A. Safety Precautions
R (1) On the center pedestal, on the ENG panel 115VU:
R (a) Put a warning notice to tell persons not to start the engine.
R (2) Make sure that the engine 1(2) shutdown occurred not less than 5
R minutes before you do this procedure.
R (3) On the overhead maintenance panel 50VU:
R (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2)
R pushbutton switch is off.
R (b) Put a warning notice to tell persons not to energize the FADEC
R 1(2).
R (4) On the AIR COND panel 30VU:
R - make sure that the APU BLEED pushbutton switch is released (OFF
R legend is on),
R - put a warning notice to tell persons not to operate the pneumatic
R system.
F 『 EEFF : ALL E Page 40280-13-43
E E May 01/04 E E ECES E F 『 EEFF : ALL E Page 40380-13-43
F 『
E C F M E
E E
E 56-5B E
E E
R R R (5) On the HP ground connector: - put a warning notice to tell persons not to pressurize the pneumatic system.
R **ON A/C ALL
Subtask 80-13-43-010-050
B. Get Access
(1) Open the fan cowl doors: (Ref. TASK 71-13-00-010-040) FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR
(2) Put the access platform.
4. Procedure_________
Subtask 80-13-43-020-050
A. Removal of the upper starter duct. (Ref. Fig. 401/TASK 80-13-43-991-300)
(1) Remove the coupling (5) that attaches the upper starter duct (25) to the pylon duct.
(2) Remove the coupling (30) that attaches the upper starter duct (25) to the starter valve.
(3) Cut the safety wire and remove the bolts (10), the washers (15), and the nuts (20) that connect the links (35) to the two sides of the upper starter duct.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 起动 STARTING(21)