 Subtask 80-11-20-860-052
 A. Aircraft Maintenance Configuration
 (1) On the center pedestal, on the ENG panel 115VU, make sure that a warning notice is in position to tell persons not to start the engine.

 (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a warning notice is in position to tell persons not to energize the FADEC 1(2).

 (3) On the AIR COND panel 30VU:

 - make sure that the APU BLEED pushbutton switch is released (ON legend is off),

 - make sure that a warning notice is in position to tell persons not to operate the pneumatic system.

 

 (4) On the HP ground connector:


 - make sure that a warning notice is in position to tell persons not to pressurize the pneumatic system.
 **ON A/C 301-399,
 Subtask 80-11-20-860-052-A
 A. Aircraft Maintenance Configuration
 (1) On the center pedestal, on the ENG panel 115VU, make sure that a warning notice is in position to tell persons not to start the engine.

 (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a warning notice is in position to tell persons not to energize the FADEC 1(2).


 F 『 EEFF : ALL E Page 40680-11-20
 E E Aug 01/05 E E ECES E

 F 『
 E C F M E
 E E
 E 56-5B E
 E E
R (3) On the AIR COND panel 30VU: R - make sure that the APU BLEED pushbutton switch is released (OFF R legend is on), R - make sure that a warning notice is in position to tell persons not R to operate the pneumatic system.

R (4) On the HP ground connector:
R - make sure that a warning notice is in position to tell persons not
R to pressurize the pneumatic system.

R **ON A/C ALL

 Subtask 80-11-20-010-056
 B. Get Access
 (1) Make sure that the fan cowl doors are open: (Ref. TASK 71-13-00-010-040) FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR
 4. Procedure
_________
 (Ref. Fig. 401/TASK 80-11-20-991-300)
 Subtask 80-11-20-420-053
 A. Installation of the starter shutoff valve
 (1) Remove the blanking caps from the air ducts and the starter shutoff valve.

 (2) Remove the blanking plugs from the electrical connectors.

 (3) Clean the mating faces of the air ducts and starter shutoff valve.

 (4) Install the starter shutoff valve (50) and the 2 V-clamps (10) and

 (40) between the upper and lower ducts.

 (5) Make sure that the flow arrow on the valve points to the starter and that the indexing slot of the valve is aligned with the lug of the upper duct.


 F 『 EEFF : ALL E Page 40780-11-20
 E E May 01/04 E E ECES E

 F  『
 E  C F M  E
 E  E


 E 56-5B E
 E E
 (6) Lubricate the threads of the V-clamp bolts with graphite grease (Material No. CP2101).

 (7) Installation of the V-clamps: CAUTION : MAKE SURE THAT THE V-CLAMP ATTACHMENTS CAN NOT TOUCH ENGINE
_______ COMPONENTS OR STRUCTURE, TO PREVENT DAMAGE.
 (a) Put the V-clamps (10) and (40) in position on the starter shutoff valve (50) and on the upper and lower ducts.
 (8) Torque the V-clamp nuts as follows:

 (a) TORQUE the nuts to between 70 and 80 lbf.in (0.79 and 0.90 m.daN)

 (b) Tap the perimeter of the V-clamps with a fiber hammer and TORQUE again the nuts.

 (c) Do this torque procedure two times.

 

 (9) Connect the 2 electrical connectors (20) and (30) to the starter shutoff valve (50). Use soft nose connector pliers only if necessary.


 Subtask 80-11-20-869-051
 B. Make sure that the work area is clean and clear of tool(s) and other items.
 Subtask 80-11-20-942-051
 C. Remove the warning notice(s).
 Subtask 80-11-20-710-053

 D. Do a dry motoring check (Ref. TASK 71-00-00-710-001).
 5. Close-up
________
 Subtask 80-11-20-410-053

 A. Close the fan cowl doors: (Ref. TASK 71-13-00-410-040)
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR

 F 『 EEFF : ALL E Page 40880-11-20
 E E May 01/04 E E ECES E

 F  『
 E  C F M  E
 E  E


 E 56-5B E
 E E
 DUCT - LOWER STARTER - REMOVAL/INSTALLATION


___________________________________________
 TASK 80-13-42-000-041
 Removal of the Lower Starter Duct
 1. Reason for the Job
 