(3) Put the links (35) in position on the two sides of the upper starter duct. Install the bolts (10), the washers (15), and the nuts (20).
F 『 EEFF : ALL E Page 40780-13-43
E E May 01/04 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
(4) Adjust the links (35), as required to avoid a preload of the duct and the links.
(5) TORQUE the nuts (20) to between 50 and 70 lbf.in (0.56 and 0.79 m.daN).
(6) Lock the links with lockwire 0.032 in. (0.8 mm) dia . (Material No. CP8001).
(7) TORQUE the nuts on the couplings (5) and (30) as follows:
(a) TORQUE the coupling nuts to between 70 and 80 lbf.in (0.79 and
0.90 m.daN).
(b) Lightly hit the perimeter of the coupling with a fiber hammer then torque the coupling nut again.
(c) Do the torque procedure two times, then torque the coupling nut again.
5. Close-up
________ Subtask 80-13-43-410-050
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the fan cowl doors: (Ref. TASK 71-13-00-410-040)
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
(3) Remove the access platform(s).
(4) Remove the warning notice(s).
F 『 EEFF : ALL E Page 40880-13-43
E E May 01/04 ERE
ECES E
F 『
E C F M E
E E
E 56-5B E
E E
DUCT - FLEXIBLE STARTER - INSPECTION/CHECK
__________________________________________
TASK 80-13-43-210-040
Visual Inspection of the Upper Starter duct
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific warning notice
No specific access platform 1 m (3 ft. 3 in.)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors
71-13-00-410-040 Closing of the Fan Cowl Doors
80-13-43-000-041 Removal of the Upper Starter Duct
80-13-43-400-041 Installation of the Upper Starter Duct
R CMM 71-00-17 (for corrective action)
3. Job Set-up
__________
Subtask 80-13-43-941-052
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a warning notice to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
F 『 EEFF : ALL E Page 60180-13-43
E E Aug 01/02 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a warning notice to tell persons not to energize the FADEC 1(2).
Subtask 80-13-43-010-054
B. Get Access
(1) Open the fan cowl doors (Ref. TASK 71-13-00-010-040): FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR
(2) Put the access platform in position.
4. Procedure
_________
Subtask 80-13-43-210-050
R A. Detailed Visual Inspection of the Upper Starter Duct R
R (1) Do a visual inspection of the upper starter duct as follows: R
R NOTE : Upper starter ducts that are removed due to damage may be sent
____ R to the shop for repair, review and possible return to service R (Ref. CMM 71-00-17).
-------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
1. Examine the upper starter duct, look for:
R A. Cracks None permitted If a crack is found, do R the weld repair at next A R check or replace the duct R (Ref. TASK 80-13-43-000-R 041) and (Ref. TASK 80-13-
43-400-041).
F 『 EEFF : ALL E Page 60280-13-43
E E Aug 01/02 E E ECES E
F 『 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM 起动 STARTING(23)