_______ PLUG. ONE TO HOLD THE OIL DRAIN PLUG ADAPTER THE OTHER TO LOOSEN/TIGHTEN THE MAGNETIC PLUG. OTHERWISE ACCIDENTAL OIL DRAINING OF THE STARTER COULD OCCUR.
 (a) Install the magnetic plug (90) in oil drain plug adapter (110) by hand. TORQUE magnetic plug (90) to between 8 and 24 lbf.in (0.09 and 0.27 m.daN).

 (b) Safety the magnetic plug (90) to the drain plug adapter (110) and starter housing with lockwire 0.032 in. (0.8 mm) dia. (Material No. CP8001) or lockwire 0.032 in. (0.8 mm) dia. (Material No. CP8002).


 Subtask 80-11-10-210-053
 D. Inspection of Starter External Surfaces.
 (1) Visually make sure there are no signs of oil leakage from the starter housing. If you find oil leaks, replace the starter (Ref. TASK 80-11-10-000-002) and (Ref. TASK 80-11-10-400-002).

 (2) Visually make sure there are no signs of oil leakage between the starter housing and the items which follow:

 - Oil fill plug adapter (50)

 - Oil overflow plug adapter (60)

 - Oil drain plug adapter (110)

 


 F 『 EEFF : ALL E Page 61180-11-10
 E E May 01/05 E E ECES E

 F 『
 E C F M E
 E E
 E 56-5B E
 E E
R (a) Oil leaks past these adapters could be caused by defective R O-rings below them. If you see any oil leakage, replace starter R (Ref. TASK 80-11-10-000-002) and (Ref. TASK 80-11-10-400-002).

R (3) Visually make sure there are no oil leaks from the knurled oil fill R plug (30) and the knurled overflow plug (80). If leaky, remove them R and make sure: R - O-ring (40) is installed and/or is in good condition R - O-ring (70) is installed and/or is in good condition
R (a) If necessary, install a new O-ring (40) and O-ring (70) on R knurled plug (30) or (80). Install plugs by hand. Make sure of R positive retention by their bayonet attachment system.
R (4) Make sure that adapters (50), (60) and (110) are correctly lockwired.
R (5) Make sure that the chains (or cables) which keep the plugs (30) and R (80) are in place and in good condition.
R (6) Make sure of correct installation and positive retention of V-clamps R (10) and (20).
 **ON A/C ALL
 Subtask 80-11-10-613-050
 E. Do the servicing of the starter, if necessary (Ref. TASK 12-13-80-610-001)
 5. Close-up
________
 Subtask 80-11-10-410-052
 A. Close Access
 (1) Make sure that the work area is clean and clear of tool(s) and other items.

 (2) Close the fan cowl door: (Ref. TASK 71-13-00-410-040) FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR

 (3) Remove the warning notice(s).


 F 『 EEFF : ALL E Page 61280-11-10
 E E Aug 01/04 E E ECES E

 F 『
 E C F M E
 E E
 E 56-5B E
 E E


 TASK 80-11-10-210-003
 Starter Inspection for a Probably FOD (Foreign Object Damage)
 1. Reason for the Job
__________________
 This check must be done if a FOD (Foreign Object Damage) is probably found:
 - Damages can cause a slow start or no start

 - This check is also necessary if there is an indication of IP Bleed Check Valve damage (cracks, missing segments or wear out of limits)


 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE  QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific  warning notice
 No specific  Torque Wrench : range 36.00 to 220.00 lbf.in
 (0.40 to 2.60 m.daN)
 B. Consumable Materials
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
Material No. CP2101  USA MIL-T-5544
 graphite grease (Ref. 70-30-00)

 C. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
36-11-41-200-001  Inspection/Check of the IP Bleed Check Valve
R  36-11-41-200-010 Check of the IP Bleed Check Valve for Condition 71-13-00-010-040 Opening of the Fan Cowl Doors 71-13-00-410-040 Closing of the Fan Cowl Doors 80-11-10-000-002 Removal of the Pneumatic Starter 80-11-10-400-002 Installation of the Pneumatic Starter 80-13-42-000-041 Removal of the Lower Starter Duct 80-13-42-400-041 Installation of the Lower Starter Duct 80-11-10-991-303 Fig. 603
 