ACTION RESULT -------------------------------------------------------------------------------
-Eject the FMGC2 floppy disk.
12. On the Data Loading Selector:
-Set the ON/OFF switch to OFF.
13.
Open the circuit breaker 10CA2 (wait for more than 5 seconds).
14.
Close the circuit breakers 10CA1 and 10CA2. **ON A/C 151-199, 201-212,
Post SB 31-1130 For A/C 201-203, Subtask 22-70-00-610-062-A
A. Downloading of the FM BITE Data
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1.
Open the circuit breakers 10CA1 and 10CA2.
2.
On the overhead panel, on the Data Loading Selector:
-Set the ON/OFF switch to ON.
3. On the overhead panel, on the Data Loading Selector:
-
Push the PREV or NEXT key until you get the indication of the FMGC1 that you can download,
-
Push the SEL CTL key.
On the display of the Data LoadingSelector:
-DB/N: PUSH NEXT/PREV indication is shown.
On the multipurpose disk drive unit:
-The < < MDDU READY > > indication is shown.
On the display of the Data LoadingSelector:
-FMGC1NOT SELECTEDindication is shown,
-FMGC1 SELECTED
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
4.
Close the circuit breaker 10CA1.
5.
On the multipurpose disk drive unit:
-Put the FM BITE DOWNLOAD TOOL (PS4084544-103) into the disk drive.
6. On the multipurpose disk drive unit:
-Eject the floppy disk.
7.
Open the circuit breaker 10CA1.
8.
On the Data Loading Selector:
-
Push the PREV or NEXT key until you get the indication of the FMGC2 that you can download,
-
Push the SEL CTL key.
9. Close the circuit breaker 10CA2.
indication is shown.
-The power-up test of the FMGC1 starts.
-At the end of this test, the triple click aural warning sounds.
On the multipurpose disk drive unit:
-
The TRANSF IN PROG indication isshown
-
The BUS n :xxxxxxx indication is shown.
NOTE : "n" is the number of the bus (1
____ to 8) in transfer. "xxxxxxx" is the number of bytes (0 to xxxxxxx).
-Then, the WAIT RESPONSE indication is shown when the transfer is completed.
On the display of the Data LoadingSelector:
-FMGC2NOT SELECTED indication is shown,
-FMGC2 SELECTED indication is shown.
-The power-up test of the FMGC2 starts.
-At the end of this test, the triple click aural warning sounds.
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
10. On the multipurpose disk drive unit:
-Put the FM BITE DOWNLOAD TOOL (PS4084544-103) into the disk drive.
11. On the multipurpose disk drive unit:
-Eject the floppy disk.
12. On the Data Loading Selector:
-Set the ON/OFF switch to OFF.
13.
Open the circuit breaker 10CA2 (wait for more than 5 seconds).
14.
Close the circuit breakers 10CA1 and 10CA2.
On the multipurpose disk drive unit:
-
The TRANS IN PROG indication is shown
-
The BUS n :xxxxxxx indication isshown.
NOTE : "n" is the number of the bus (1
____ to 8) in transfer. "xxxxxxx" is the number of bytes (0 to xxxxxxx).