2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s) PS4084544-103 1 FM BITE DOWNLOAD TOOL YV68A110 1 PORTABLE DATA LOADER
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power
3. Job Set-up
__________ Subtask 22-70-00-860-071
A. Aircraft Maintenance Configuration
(1)
Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
(2)
Make sure that the electronics rack ventilation is in operation.
1EFF : ALL 1 22-70-00Page 301 1 1 May 01/05 1 1 1CES 1
(3) Make sure that the aircraft is in the ground configuration.
Subtask 22-70-00-865-075
B. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------
PANEL ------ DESIGNATION ------------------------------------------------------- IDENT. LOCATION------------------
49VU AUTO FLT/FMGC/1 10CA1 B02
49VU AUTO FLT/MCDU/1 11CA1 B01
121VU AUTO FLT/FMGC/2 10CA2 M17
121VU AUTO FLT/MCDU/2 11CA2 N20
Subtask 22-70-00-865-076
C. Open, safety and tag this(these) circuit breaker(s):
------PANEL ------ -------------------------------------------------------DESIGNATION ------------------------------------------------------- ------------------IDENT. LOCATION------------------
121VU COM NAV/ACARS/MU 2RB L06
4. Procedure_________
Subtask 22-70-00-610-057
A. Downloading of the FM BITE Data
-----------------------------------ACTION --------------------------RESULT ------------------
-------------------------------------------------------------------------------
1. On the center pedestal, on the MCDU1(2):
-turn the BRT knob to adjust the brightness.
2.
Open the circuit breakers 10CA1, MCDU1 and 2 go blank. 10CA2, 11CA1 and 11CA2.
3.
On the PORTABLE DATA LOADER (YV68A110):
-set the ON/OFF switch to OFF.
-connect the connecting cable to the loader connector.
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
4. On the panel 52VU:
-remove the FMS LOAD blanking plate.
-connect the connecting cable to the SYST1 connector.
5.
Close the circuit breaker 11CA1.
6.
On the portable data loader:
-set the ON/OFF switch to ON.
7.
Close the circuit breaker 10CA1.
8.
On the portable data loader:
-put the FM BITE DOWNLOAD TOOL (PS4084544-103) into the disk drive.
9. On the portable data loader:
-eject the floppy disk.
-set the ON/OFF switch to OFF.
10.
Open the circuit breakers 10CA1 and 11CA1.
11.
On the panel 52VU:
-disconnect the connecting cable from the SYST 1
-connect the connecting cable to the SYST 2 connector
12.
Close the circuit breaker 11CA2.
13.
On the portable data loader:
-set the ON/OFF switch to ON.
14. Close the circuit breaker 10CA2.
On the portable data loader:
-
the MDDU READY indication is shown.
-
the power-up test of the FMGC 1 starts.
-at the end of this test, the triple click aural warning sounds.
-On the portable data loader:
-the TRANS IN PROG indication is shown
-then, the WAIT RESPONSE indication isshown when the transfer is completed.
On the portable data loader:
-
the MDDU READY indication is shown.
-
the power-up test of the FMGC 2 starts.
-at the end of this test, the triple click aural warning sounds.
-------------------------------------------------------------------------------
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AUTO FLIGHT 自动飞行2(69)