曝光台 注意防骗
网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
L1 ENG FIRE P/B (AFFECTED)...............................................................................................PUSH
L2 Aural warning stops.
ENG FIRE pushbutton remains on, as long as fire is detected.
FADEC is no longer supplied.
L1 AGENT 1+2.........................................................................................................................DISCH
ENG MASTER (OPPOSITE SIDE).........................................................................................OFF
The following items are not displayed on the ECAM, if the APU is not running:
ATC (VHF 1).....................................................................................................................NOTIFY
L2Notify ATC of the nature of the emergency, and state intensions.
Only VHF 1 is available on batteries.
L1CABIN CREW (PA)............................................................................................................ ALERT
IF EVAC RQRD:
EVAC COMMAND..............................................................................................................ON
APU MASTER SW...........................................................................................................OFF
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
FIRE PROTECTION
A318/A319/A320/A321 FLEET PRO-ABN-26 P 6/176
FCOM 19 AUG 10
ENG 1(2) FIRE
(IN FLIGHT)
Applicable to: ALL
LAND ASAP
THR LEVER (AFFECTED)...........................................................................................................IDLE
ENG MASTER (AFFECTED)........................................................................................................ OFF
L2 LP and HP valves close.
L1 ENG FIRE P/B (AFFECTED).....................................................................................................PUSH
L2 Aural warning stops.
ENG FIRE pushbutton remains on, as long as a fire is detected.
FADEC is no longer supplied. So, the THR LEVER ... IDLE line reappears, even if the thrust lever is
at idle.
L1 AGENT 1 AFTER 10 S.............................................................................................................DISCH
L2 The 10 s delay allows N1 to decrease, reducing nacelle ventilation, and thereby increasing the
effect of the agent.
Automatic countdown on the ECAM.
L1 ATC........................................................................................................................................NOTIFY
L2Notify ATC of the nature of the emergency, and state intentions
L1 IF FIRE AFTER 30 S:
AGENT 2.............................................................................................................................DISCH
L2 Discharge the second agent, if the fire warning remains 30 s after the discharge of the first
agent.
L12
ASSOCIATED PROCEDURES
ENG 1(2) SHUTDOWN
Do not attempt to restart the engine.
For the after ENG SHUTDOWN procedure, see the ENG section. (Refer to PRO-ABN-70-I After
ENG 1(2) SHUT DOWN).
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
FIRE PROTECTION
A318/A319/A320/A321 FLEET PRO-ABN-26 P 7/176
FCOM 19 AUG 10
APU FIRE
Applicable to:
LAND ASAP
APU FIRE P/B............................................................................................................................PUSH
L2 APU LP valve closes.
Aural warning stops.
APU FIRE pb-sw remains on, as long as a fire is detected.
L1 AGENT AFTER 10 S................................................................................................................ DISCH
L2 The 10 s delay allows the airflow to decrease, which increases the effect of the agent.
Automatic countdown on the ECAM.
L1MASTER SW...............................................................................................................................OFF
L2 Do not attempt to restart the APU.
STATUS
Other INOP SYS
APU
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
FIRE PROTECTION
A318/A319/A320/A321 FLEET PRO-ABN-26 P 8/176
FCOM 19 AUG 10
APU FIRE
Applicable to: ,
LAND ASAP
APU FIRE P/B............................................................................................................................PUSH
L2 APU LP valve closes.
Aural warning stops.
APU FIRE pb-sw remains on, as long as a fire is detected.
L1 AGENT AFTER 10 S................................................................................................................ DISCH
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
A320机组操作手册FLIGHT CREW OPERATING MANUAL 9(7)