SMOKE/FUMES/AVNCS SMOKE - GENERAL (Cont'd)
IF AIR COND SMOKE SUSPECTED:
APU BLEED..........................................................................................................................OFF
BLOWER and EXTRACT.....................................................................................................AUTO
Note: When both BLOWER and EXTRACT are in the OVRD position, a single pack may not
be able to maintain the cabin pressure.
CARGO FWD ISOL VALVE................................................................................................... OFF
To prevent a cargo smoke warning from being triggered due to cabin smoke.
PACK 1................................................................................................................................. OFF
If smoke continues:
PACK 1.............................................................................................................................. ON
PACK 2.............................................................................................................................OFF
If smoke still continues:
PACK 2........................................................................................................................ON
Restore normal configuration if PACK 2 is not suspected to cause smoke
BLOWER and EXTRACT....................................................................................... OVRD
SMOKE/FUMES REMOVAL....................................................................................... CONSIDER
IF CAB EQUIPMENT SMOKE SUSPECTED:
If smoke continues:
EMER EXIT LIGHT............................................................................................................ON
COMMERCIAL..................................................................................................................OFF
SMOKE DISSIPATION............................................................................................... CHECK
FAULTY EQPT.........................................................................................SEARCH/ISOLATE
Once the cabin has been secured, try to find the smoke source and isolate it.
Cabin lights, reading lights, passenger systems, galleys have dedicated control C/B in the
cabin or cockpit.
If smoke still continues or if faulty equipment confirmed isolated:
COMMERCIAL....................................................................................................... NORM
SMOKE/FUMES REMOVAL.................................................................................CONSIDER
At any time of the procedure, considered applying the SMOKE/FUMES REMOVAL
procedure.
To be continued on next page
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
FIRE PROTECTION
A318/A319/A320/A321 FLEET PRO-ABN-26 P 138/176
FCOM 19 AUG 10
SMOKE/FUMES/AVNCS SMOKE - GENERAL (Cont'd)
IF SMOKE SOURCE CANNOT BE DETERMINED AND STILL CONTINUES OR
AVNCS/ELECTRICAL SMOKE SUSPECTED:
ELEC EMER CONFIG................................................................................................ CONSIDER
As a last attempt, the flight crew can set the electrical emergency configuration to possibly
isolate or minimize the smoke source.
IF SMOKE disappears within 5 min:
NORMAL VENTILATION..............................................................................................RESTORE
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
ABNORMAL AND EMERGENCY PROCEDURES
FIRE PROTECTION
A318/A319/A320/A321 FLEET PRO-ABN-26 P 139/176
FCOM 19 AUG 10
SMOKE/FUMES/AVNCS SMOKE - GENERAL
Applicable to: MSN
This paper procedure includes all the steps of the AVIONICS SMOKE ECAM procedure.
Apply this paper procedure when:
The flight (cabin) crew suspect that smoke is coming ‐ from the avionics, and/or the air
conditioning, and/or the cabin equipment.
‐ The AVIONICS SMOKE ECAM caution is triggered, or, at the latest, after completing the
immediate actions of the AVIONICS SMOKE ECAM procedure (before reaching the 5–minutes
countdown procedure line)
There is a smell of smoke/fumes in the cockpit:
• If the smell is similar to that of orange peels, suspect a toxic leak of rain repellent fluid.
• If the smell is similar to that of pine needles, suspect a non-toxic leak.
If any other ECAM SMOKE alert triggers (CARGO, ...), the crew must first apply the ECAM
procedure, then consider applying this paper procedure.
Note that these ECAM alerts may be caused by another source, that should usually first be
detected by the flight crew/cabin crew/avionics smoke detectors.