SWITCHES SET  CPG. seconds after power turn-on may induce
an error into the bias calculation and
CAUTION cause the MMS to drift.
2. OPR mode select switch  FWD. Allow MMS
• When MMS is operating but not being to stabilize.
used, the sight shall be slaved FWD to
prevent the payload assembly from
contacting and damaging the azimuth 3. MNL/SLAVE switch  Press. Observe MMS
and elevation stops. slews FWD.
• Turn MMS mode select switch off if
MMS fails to respond to control 4. Laser codes  Check; enter as required.
commands.
1. LASER ARM/STBY/OFF switch  OFF. 5. Laser ARM/STBY/OFF switch  STBY
2. FIRST/LAST switch  As desired. 6. MMS current laser code  Select appropriate
code as required.
3. VIDEO MMS SYM INTEN toggle switch 
MAN.
4. VIDEO GAIN toggle switch  As desired. 4-9. TIS MANUAL SETUP PROCEDURES.
5. VIDEO LEVEL toggle switch  AUTO. 1. MFD contrast and brightness  Adjust as
desired.
6. OPR mode select switch  OFF.
7. ALFGL switch  OFF. 2. Reposition MMS LOS to bland background.
8. TIS INTEG switch  OFF.
3. Manually reduce GAIN to full negative
(minimum of 10 seconds), simultaneously
9. LMC switch  OFF. activate ALE until horizontal lines are reduced
to a minimum.
10. ALE switch  OFF.
4. Realign MMS LOS to a high contrast
4-8. ENGINE RUNUP  MMS STARTUP background.
CHECKS  CPG.
1. MMS key  Press. 5. Adjust GAIN to positive until desired target
definition is achieved.
NOTE
6. Manually or automatically adjust FOCUS to
• MMS runup requires 3-phase AC power desired clarity.
from the AC generator or external AC
power. Prior to turning the MMS on, verify
required power is available. 4-10. MMS MANUAL BORESIGHT.
• When MMS power is turned on, the
system immediately checks the output of A manual boresight is recommended prior to the first
the LOS CONT switch on the CPG cyclic automatic boresight on a power cycle, when LOS reticle
control grip and supplies an opposite bias shifts off target upon FOV or sensor change, or when a
in order to zeroize the LOS output. REBORESIGHT message remains after automatic
4-30
TM 1-1520-248-10
boresight. If any of the previous conditions exists, • TIS HOT message may remain as an
accomplish a manual boresight as follows: advisory message. Disregard if TIS
picture meets operational requirements.
NOTE
1. FOV SEL switch  Select narrow field of
• If required, TIS setup procedures should view for both TV and TIS sensors.
be performed prior to boresighting to
obtain proper TIS picture. 2. OPR mode select switch  PREFLT.
• MMS is boresighted automatically in TV 3. LASER ARM/STBY/OFF switch  ARM.
NFOV and TIS NFOV only. Manual
boresighting can be accomplished in wide 4. BRST AUTO key  Press. Resolution targets
or narrow. Each sensor should be for each sensor appear for approximately 6
boresighted in WFOV prior to NFOV seconds each then disappear. Check clear
• Only one sensor FOV can be boresighted and in focus.
at a time in BRST MAN. To boresight
each, it is necessary to deselect BRST 5. LASER fire switch  Press and hold before
MAN, select the other sensor and/or FOV, second resolution target disappears.
then reselect BRST MAN.
6. TV and TIS  Verify laser spot size (TV: 1/16
1. OPR mode select switch  PREFLT. - 1/8 inch, TIS: 2-3 lines for MSP, 3-4 lines
for IMSP). Verify target gate displays sizes
2. LASER ARM/STBY/OFF switch  ARM. and tracks laser spot. There should be no
jitter of gate and spot should be centered in
3. TV/TIS switch  Select desired sensor. gate (fig. 4-16 and 4-17).
4. FOV SEL switch  Select desired field of NOTE
view.
Repeat a manual boresight; then repeat
5. BRST MAN key  Press. Resolution target automatic boresight procedure if hot spot is
appears for approximately 6 seconds then shifted from center position or target gate
disappears. Check clear and in focus. does not size and track laser spot. MMS
maintenance is required if laser spot
6. LASER fire switch  Press and hold. Adjust displays incorrectly (too large or small).
LOS reticle until it is centered over the laser
spot by adjusting the LOS CONT switch. 7. BRST COMPLETE message  Appears in
Then release LASER fire switch. status block.
7. BRST MAN  Press to deselect manual 8. LASER fire switch  Release.
boresight.
9. LASER ARM/STBY/OFF switch  Set as
 
中国航空网 www.aero.cn