READOUT GREEN AMBER WHITE HALF INTENSITY
MAGENTA
AMBER DASHES
XX KVA
Generator
loaded
Generator
overload
Generator not
loaded Insufficient data Invalid data
XXX V
Voltage
in range
_ Invalid data
XXX HZ _ Invalid data
Insufficient data
Frequency Insufficient data
in range
Voltage not
in range
Frequency
not in range
BUS Bus powered Bus not powered _
or voltage low Invalid data
_
Flow Lines
Green -- Bus energized.
Blank -- Bus not energized.
BRT
Vol. 1 07--20--6
ELECTRICAL
AC Electrical System REV 1, Jan 13/03
Flight Crew Operating Manual
CSP C--013--067
AC Electrical System Synoptic Page
Figure 07---20---3 Sheet 2
AC ELECTRICAL
GEN
1
GEN
IDG1 APU IDG2
GEN
2
DISC
ESS BUS
SERV BUS
BUS 1 BUS 2
ADG BUS
V
HZ
115
400 ADG
DISC
KVA
V
HZ
000
KVA
V
HZ
000
KVA
V
HZ
000
SHED
AUTO
XFER
FAIL
SHED (white)
Indicates that service bus is not powered.
DISC (white)
Indicates that IDG has been disconnected.
AUTO XFER OFF (white)
Indicates that corresponding automatic
transfer has been selected off.
AUTO XFER FAIL (amber)
Indicates that corresponding automatic
transfer has failed.
AC Electrical Page
ADG Features
Displayed when ADG voltage is more than 10 volts
and frequency is more than 300 Hz.
ADG
EICAS
OUTLINE GREEN WHITE
Voltage and frequency
digital readouts green
EICAS DIGITAL
READOUT GREEN WHITE
XXX V
Between 108 and
130 volts
XXX HZ
Less than 108 volts or
more than 130 volts
ADG BUS
AMBER DASHES
Invalid data
Between 360 and
440 Hz
Less than 360 Hz or
more than 440 Hz Invalid data
Voltage or frequency
digital readouts white
ADG outline green ADG outline white
BRT
AUTO
XFER
OFF
Vol. 1 07--20--7
ELECTRICAL
AC Electrical System Sep 09/02
Flight Crew Operating Manual
CSP C--013--067
AC Electrical System Synoptic Page
Figure 07---20---3 Sheet 3
AC ELECTRICAL
GEN GEN GEN
ESS BUS
SERV BUS
BUS 1 BUS 2
KVA
V
HZ
30
115
400
EXT
AC
KVA
V
HZ
000
KVA
V
HZ
16
115
400
KVA
V
HZ
18
115
400
SERVICE
CONFIGURATION
AC Electrical Page
1
IDG1 APU IDG2
2
DISC DISC
SERVICE CONFIGURATION (green)
Displayed when external AC power is available
and the AVAIL switchlight on the external
AC service panel has been selected.
Only the AC service bus will be powered.
External AC Power Features
Displayed when external AC voltage is more
than 10 volts and frequency is more than 50 Hz.
EICAS
OUTLINE
GREEN WHITE HALF INTENSITY
MAGENTA
EXT Invalid data
AC
External AC available
or in use
EICAS DIGITAL
READOUT GREEN AMBER WHITE
HALF INTENSITY
MAGENTA
AMBER DASHES
XX KVA Loaded Overload Not loaded Insufficient data Invalid data
XXX V
Between 106
and 124 volts
_ Invalid data
XXX HZ Between 370 _ Invalid data
and 430 Hz
Less than 106 volts or
more than 124 volts
_
Less than 370 Hz or _
more than 430 Hz
External AC not available
and not in use
BRT
Vol. 1 07--20--8
ELECTRICAL
AC Electrical System Sep 09/02
Flight Crew Operating Manual
CSP C--013--067
AC Electrical System --- EICAS Indications (Generators) <1001>
Figure 07---20---4
IDG 1 or 2 caution (amber)
Indicates that IDG has low oil pressure
or high oil temperature.
GEN 1 or 2 OVLD caution (amber)
Indicates that generator control unit has
detected a load of greater than 40 kVA.
GEN 1 or 2 OFF caution (amber)
Indicates that generator is off.
APU GEN OVLD caution (amber)
Indicates that generator control unit has
detected a load of greater than 40 kVA.
APU GEN OFF caution (amber)
Indicates that APU generator is off and
APU is ready to load.
Primary Page
IDG 1 or 2 DISC status (white)
Indicates that IDG has been disconnected,
either automatically or manually.
Status Page
IDG 1 DISC
IDG 2 DISC
BRT
IDG 1
IDG 2
GEN 1 OFF
 