When spring loaded switch 10PR is set to ON and refuel
door open, relay 5PR is energized by HOT BUS 701PP.
Relay 8PR is energized, allowing refueling busbars to
be supplied by HOT BUS 701PP.
Relay 11PR is energized by 501PP via mode selector 3QU
so that relay 5PR remains energized.
Time delay closing relay 12PR is energized by 701PP.
When it closes after 10mn, refueling power is
automatically cut off even if refuel door is still
open.
TMUELCB02-T03 LEVEL 3
EFFECTIVITY 24-67-00 Page 6
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 432
ALL
AC AND DC LOAD DISTRIBUTION - REFUELING ON BATTERY - BATTERY ONLY CONFIGURATION
TMUELCB02-P03 LEVEL 3
EFFECTIVITY 24-67-00 Page 7
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 433
ALL
SELF EXAMINATION
In which configuration is refueling power supply
automatically cut off ten minutes after?
A - Refueling busbars supplied by service
bus 601PP.
B - Refueling busbars supplied by hot bus
701PP.
C - Both configurations.
TMUELCB02 LEVEL 3
EFFECTIVITY 24-67-00 Page 8
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 434
ALL
24 - ELECTRICAL POWER
24-22-00 ECAM ELECTRICAL POWER INTERFACES
- ELECTRICAL GENERATION
INTERFACE UNIT (EGIU)
CONTENTS:
Presentation
IDG1 or IDG2
APU GEN
External Power
TMUELBU01 LEVEL 3
EFFECTIVITY 24-22-00 Page 1
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 435
ALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU)
PRESENTATION
The function of the Electrical Generation Interface
Unit is to convert analog and discrete signals from
the Generator Control Unit and Ground Power Control
Unit into ARINC 429 data.
Two identical EGIUs are used.
Each one consists of two isolated channels:
- channel 1 is allocated to IDG1 or IDG2.
- channel 2 is allocated to APU Generator or
External Power.
TMUELBU01-T01 LEVEL 3
EFFECTIVITY 24-22-00 Page 2
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 436
ALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU) -
PRESENTATION
TMUELBU01-P01 LEVEL 3
EFFECTIVITY 24-22-00 Page 3
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 437
ALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU)
IDG1 OR IDG2
The information provided to the SDAC is shown on the
screen.
The parameters are displayed on the ECAM system.
TMUELBU01-T02 LEVEL 3
EFFECTIVITY 24-22-00 Page 4
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 438
ALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU) - IDG1 OR
IDG2
TMUELBU01-P02 LEVEL 3
EFFECTIVITY 24-22-00 Page 5
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 439
ALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU)
APU GEN
The information provided to the SDAC is shown on the
screen.
The parameters are displayed on the ECAM system.
TMUELBU01-T03 LEVEL 3
EFFECTIVITY 24-22-00 Page 6
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 440
ALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU) - APU GEN
TMUELBU01-P03 LEVEL 3
EFFECTIVITY 24-22-00 Page 7
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 441
ALL
ECAM ELECTRICAL POWER INTERFACES - ELECTRICAL GENERATION INTERFACE UNIT (EGIU)
EXTERNAL POWER
The information provided to the SDAC is shown on the
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
ATA 24 ELECTRICAL POWER(48)