oil pressure increases, the cooler bypass valve opens;
oil runs in the IDG internal circuit.
As the oil warms up, the cooler bypass valve closes
and the oil flows through the fuel/oil heat exhanger.
TMUELAD04-T02 LEVEL 3
EFFECTIVITY 24-21-00 Page 4
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 102
ALL
AC GENERATION - IDG COOLING SYSTEM - COLD CONDITIONS
TMUELAD04-P02 LEVEL 3
EFFECTIVITY 24-21-00 Page 5
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 103
ALL
AC GENERATION - IDG COOLING SYSTEM
FILTER CLOGGED
A clogged filter indication is provided by a local
visual Delta Pressure pop-out Indicator (DPI).
In case of clogging indication, a DPI reset can be
done in some conditions and associated with maintenance
procedures.
When the filter is clogged, the relief valve opens.
TMUELAD04-T03 LEVEL 3
EFFECTIVITY 24-21-00 Page 6
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 104
ALL
AC GENERATION - IDG COOLING SYSTEM - FILTER CLOGGED
TMUELAD04-P03 LEVEL 3
EFFECTIVITY 24-21-00 Page 7
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 105
ALL
AC GENERATION - IDG COOLING SYSTEM
TEMPERATURE AND PRESSURE MONITORING
For overheat detection, oil temperature sensors
monitor the temperature of both input and output oil.
A pressure switch operates in the event of a loss of
charge oil pressure.
TMUELAD04-T04 LEVEL 3
EFFECTIVITY 24-21-00 Page 8
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 106
ALL
AC GENERATION - IDG COOLING SYSTEM - TEMPERATURE AND PRESSURE MONITORING
TMUELAD04-P04 LEVEL 3
EFFECTIVITY 24-21-00 Page 9
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 107
ALL
SELF EXAMINATION
When does the cooler bypass valve open?
A - When an overtemperature is detected.
B - During cold conditions operation.
C - When the filter is clogged.
TMUELAD04 LEVEL 3
EFFECTIVITY 24-21-00 Page 10
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 108
ALL
24 - ELECTRICAL POWER
24-21-00 AC GENERATION - IDG MONITORING
CONTENTS:
Temperature Monitoring
Temperature Rise Indication
Pressure Monitoring
Self Examination
TMUELAE03 LEVEL 2
EFFECTIVITY 24-21-00 Page 1
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 109
ALL
AC GENERATION - IDG MONITORING
TEMPERATURE MONITORING
If an overtemperature is detected at the IDG outlet,
the associated alarms are triggered.
If the temperature rises above 147°C, the ELEC ECAM
page is automatically displayed and the temperature
indication flashes. If the temperature exceeds 180°C,
the indication turns from green to amber.
Above 185°C, the MASTER CAUTION and IDG FAULT lights
come on, the single chime is triggered.
TEMPERATURE RISE INDICATION
If the temperature rise indication is over a given
limit, a signal is sent to the CFDIU through the Ground
Power Control Unit.
GPCU: Ground Power Control Unit.
CFDIU: Centralized Fault Display Interface Unit.
Message on the MCDU: IDG 1 (or 2) HIGH DELTA TEMP
(class 2 failure).
PRESSURE MONITORING
In case of loss of charge oil pressure the
corresponding indications and warnings are triggered
only when the corresponding engine is running.
The low pressure warning is inhibited, for IDG
input speed below 2000 RPM
(Normal input speed range: between 4500 and 9120 RPM).
TMUELAE03-T01 LEVEL 2
EFFECTIVITY 24-21-00 Page 2
May 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 24 ELECTRICAL POWER
UF94200
EFFECTIVITY Page 110
ALL
AC GENERATION - IDG MONITORING
TMUELAE03-P01 LEVEL 2
EFFECTIVITY 24-21-00 Page 3
May 31/00
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:
ATA 24 ELECTRICAL POWER(12)